TOA Electronics SSDV-3328 Typical Horizontal Vent Installation, See on Page 14 or on

Models: SSDV-3328

1 36
Download 36 pages 20.03 Kb
Page 19
Image 19
See Figure 18 on Page 14 or Figure 21 on

Building

Support Brackets

 

 

Support

 

Horizontal / Inclined Run

 

Framing

 

 

SV4.5HT-2

SV4.5E90

 

 

Termination

 

 

Shown

Elbow

 

 

 

 

 

 

 

SV4.5L6/12/24/36/48

 

Ceiling

 

Vent Sections

Exterior

uFirestop / Spacer

Wall

Vertical

SV4.5VF

Support Bracket Spacing

 

Rise

 

 

 

Every 5 ft (1.52 m)

 

 

 

 

 

 

uWhen Using Secure Flex,

 

 

 

Use Firestop / Spacer SF4.5VF

SV4.5HT-2

 

 

 

 

See Figure 18 on Page 14 or Figure 21 on

Termination

 

Page 15 for vertical vent section support.

Shown

 

 

Fireplace

 

Figure 31 - TYPICAL HORIZONTAL VENT INSTALLATION

B. Frame exterior wall opening -

Locate the center of the vent outlet on the exterior wall according to the dimen- sions shown in Figure 14 on Page 11. Cut and/or frame an opening, 10-1/2" x 12-1/8" (267 mm x 308mm) inside dimensions, about this center.

C. Frame ceiling opening - If the vertical route is to penetrate a ceiling, use plumb line to locate the center above the appliance. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267 mm x 267

mm)inside dimensions, about this center (refer to Figure 19 on Page 15).

D. Attach vent components to appliance - To attach a vent component to the appliance collar, align the dimpled end over the collar, adjust- ing the radial alignment until the four locking dimples are aligned with the inlets of the four incline channels on the collar (refer to Figure 20 on Page 15).

Push the vent component against the collar until it fully engages, then twist the component clockwise, running the dimples down and along the incline channels until they seat at the end of the channels.

The unitized design of the Secure Vent components will engage and seal both the inner and outer pipe elements with the same procedure. Sealant and securing screws are not required.

Note: An elbow may also be attached to the appliance collar. Attach in the same manner as you would a vent section.

E. Attach vent components to each other - Other vent sections may be added to the pre- viously installed section in accordance with the requirements of the vent tables. To add another vent component to a length of vent run, align the dimpled end of the component over the inclined channel end of the previously installed section, adjusting the radial alignment until the four lock- ing dimples are aligned with the inlets of the four incline channels of the previous section.

Push the vent component against the previous section until it fully engages, then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels.This seating position is indicated by the alignment of the arrow and dimple as shown in Figure 20 on Page 15.

F. Install firestop/spacer at ceiling -

When using Secure Vent, use SV4.5VF firestop/ spacer at ceiling joists; when using Secure Flex, use SF4.5VF firestop/spacer.

If there is living space above the ceiling level, the firestop/ spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the firestop/ spacer must be installed on the top side of the joist. Route the vent sections through the framed opening and secure the firestop/spacer with 8d nails or other appropriate fasteners at each corner.

Remember to maintain 1" (25 mm) clearance to combustibles, framing members, and attic or ceiling insulation when running vertical chimney sections.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

G. Support the vertical run sections - See Section E on Page 15.

H. Change vent direction - At transition from or to a horizontal/inclined run, install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element. Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any of the previously connected vent sections. See Figure 22 on Page 16.

I. Continue installation of horizontal/inclined sections - Continue with the installation of the straight vent sections in horizontal/inclined run as described in Step E. Install support straps every 5 ft. (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape. See Figure 31. It is very important that the horizontal/inclined run be maintained in a straight (no dips) and recommended to be in a slightly elevated plane, in a direction away from the fireplace of 1/4" rise per foot (20 mm per meter) which is ideal, though rise per foot run ratios that are smaller are acceptable all the way down to at or near level.

It is important to maintain the required clear- ances to combustibles: 1" (25 mm) at all sides for all vertical runs; and 3" (76 mm) at the top, 1" (25 mm) at sides, and 1" (25 mm) at the bottom for all horizontal/inclined runs.

19

Page 19
Image 19
TOA Electronics SSDV-3328 installation instructions Typical Horizontal Vent Installation, See on Page 14 or on