11. Technical Specifications
Frequency response (1) +/- 3dB
Recommended Amplifier Power
Power Handling
Sensitivity (1) 2.83 volt @ 1m
Maximum SPL (3)
@1m
Impedance
DI Averaged (PCQ)
@1kHz (ISO)
@2kHz (ISO)
@4kHz (ISO)
@8kHz (ISO)
@16kHz (ISO)
Q Averaged (PCQ)
@1kHz (ISO)
@2kHz (ISO)
@4kHz (ISO)
@8kHz (ISO)
@16kHz (ISO)
Distortion
0.1Full Power 250 Hz
1000 Hz
10000 Hz
0.01Full Power 250 Hz
1000 Hz
10000 Hz
Driver Complement
Crossover Point
70Hz - 25kHz
45Hz - 25kHz (with Tx2 controller)
200 - 400 watt / 8 ohm |
| |
Average(2) | Programme Peak (10ms) | |
200 watt | 400 watt | 800 watt |
97 dB |
|
|
Average | Peak |
|
120 dB | 126 dB |
|
Nominal |
| 8.0 ohm |
Minimum |
| 6.1 ohm |
8.3, 250 Hz - 16 kHz |
| |
7.1 |
|
|
9.3 |
|
|
10.1 |
|
|
12.6 |
|
|
14.2 |
|
|
9.5, 250 Hz - 16 kHz |
| |
5.1 |
|
|
8.5 |
|
|
10.2 |
|
|
18.2 |
|
|
26.3 |
|
|
2nd Harmonic | 3rd Harmonic | |
0.17% |
| 0.14% |
1.00% |
| 1.25% |
1.78% |
| 0.04% |
2nd Harmonic | 3rd Harmonic | |
0.08% |
| 0.06% |
0.32% |
| 0.89% |
0.56% |
| 0.01% |
1 x 12” (300mm) Constant Directivity Dual Concentric Type number 3142
Passive 1.5 kHz
2nd order high pass, 2nd order low pass Halogen HF protection
Enclosure | 38.7 litre vented, 15mm birch plywood (T12), MDF (i12) |
Finish | Textured black\grey paint |
Protective Grille | Perforated steel, black with 58% free air flow |
Connectors | 2 x Speakon NL4MPR IN/OUT |
Fittings | T12: 1 x Recessed carrying handle |
| T12: 1 x 35mm pole mounting socket |
| T12/i12: 8 x M8 flying inserts & 1x M8 pullback point |
Dimensions | 486mm(H) x 370mm(W) x 385mm(D) |
| 19.13ins(H) x 14.57ins(W) x 15.15ins(D) |
Weight | 20 Kg (44 lbs) |
NOTES:(1) Average over stated bandwidth. Measured at 1m on axis, in an anechoic chamber.
(2)Long term power handling capacity as defined in EIA standard RS - 426A.
(3)Unweighted pink noise input, measured at 1m
Tannoy operate a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed published specifications which Tannoy reserve the right to alter without prior notice.
Please verify the latest specifications when dealing with critical applications.