Troubleshooting / Specifications

Troubleshooting

If the PCS150R is not connecting to the network during system setup, i.e., the Eth0 IP field in the System Information display (see setup procedure on page 12) is blank:

1.Check the ETHERNET-0 connector on the rear panel of the PCS150R. Make sure the cable connection is tight and secure.

2.Observe the green LED on the ETHERNET-0 port. Once the PCS150R is connected to the network, the LED will be lit continuously.

3.Contact the network administrator to verify the network status.

Specifications

Dimensions

 

Height:

1.692 inches (42.977 mm)

Width:

19.0 inches (482.6 mm) (for EIA standard 19-inch rack mount)

Depth:

8.5 inches (215.9 mm)

Weight:

3.45 pounds (1.56 kgrms) rack-only weight

Environmental Storage Conditions

Temperature:

-20° to 70° Celsius

 

-4° to 158° Fahrenheit

Humidity:

95% non-condensing

Environmental Operating Conditions

Temperature (Tma): 0° to 40° Celsius

 

32° to 104° Fahrenheit

Humidity:

95% non-condensing

Electrical

 

 

DC Input:

 

+12V DC @ 4.0 Amps

Impedance at ASI Out jack:

75 ohms

Level at ASI Out jack:

800 mv

Ethernet:

 

10/100/1000BaseT

Note: Design and specifications subject to change without prior notice.