Rack Installation
Typical PCS150R Rack Installation
1.Carefully slide the chassis into a standard
2.Use all four mounting screws to secure the chassis to the rack.
Rack-mount Considerations
A. Elevated Operating Ambient
If installed in a closed or
B. Reduced Air Flow
Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. To ventilate the system nor- mally and avoid overheating, leave at least 1 inch (2.5 cm) on each side (including top and bottom) of the PCS150R. Do NOT stack other equipment on the top of the PCS150R unit.
C. Circuit Overloading
Consideration should be given to the con- nection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
D. Reliable Earthing
Maintain reliable earthing of
E.Mains Outlet Earthing
The apparatus with Class I construction must be connected to a mains socket outlet with a protective earthing connection.
9 |