VS-900 Architects and Engineering Specifications v1.0

3.16 CONFERENCE

The Conference function shall allow any Master Station or Telephone Master Station to initiate simultaneous conversation with up to two other Master Stations or Telephone Master Stations.

3.17 EMERGENCY CONFERENCE

The Emergency Conference function shall allow any Master Station or Telephone Master Station to initiate simultaneous conversation with a pre-programmed group of up to three other Master Stations or Telephone Master Station with a short key sequence.

3.18 PAGING

The Paging function shall allow Master Stations or Telephone Master Stations to broadcast to pre-programmed zones or all-zones of multiple Sub-stations* and/or external public address equipment. It shall be possible to initiate the Paging function with the Master Station handset either off-hook or on-hook.

*External amplifier required.

3.18.1 ZONE PAGING

The Zone Paging function shall allow paging to up to nineteen (19) individual zones established in system programming by combining Sub-stations with external public address system equipment. Up to 1,024 Sub-stations and up to 16 external control outputs can be registered per zone. It shall be possible to randomly select two or more individual zones simultaneously (up to 19). A paging pre-announcement tone shall be transmitted to the selected zones.

3.18.2 ALL-ZONE PAGING

The All-Zone Paging function shall allow simultaneous broadcast to all programmed zones of Sub-stations and external public address equipment. Sub-stations and external public address equipment not assigned to zones shall not receive the All-Zone broadcast. A paging pre- announcement tone shall be transmitted to all zones. The Master Station shall initiate the Paging function with the handset either off-hook or on-hook and terminate the Paging function by replacing the handset or pressing the [C] key.

3.18.3 EMERGENCY PAGING

The Emergency Paging function shall allow simultaneous broadcast to all connected Master Stations, Sub-stations, and external public address equipment. It shall be possible to restrict access to the Emergency Paging function in system programming. A distinct “Emergency” paging pre-announcement tone shall be transmitted to all Sub-stations, Master Stations, Telephone Master Stations, and external public address equipment. A continuous ringing tone shall sound at each Telephone Master Station.

3.18.4 BROADCAST PRIORITY

The broadcast priority from highest to lowest shall be Emergency Paging, Emergency Conference, External Source Distribution and All-Zone Paging. A higher priority broadcast shall interrupt all lower priority paging or broadcast functions.

3.18.5 PAGING TIME-OUT

The Paging Time-Out function shall automatically terminate Zone and All-Call paging calls that exceed a pre-programmed time limit from ten (10) to nine-hundred and ninety (990) seconds in ten (10) second intervals. The Paging Time-Out function shall not affect the Emergency Paging function.