3.21 CONVERSATION RECORDING
The Conversation Recording function shall allow individual recording of each Master Station, Telephone Master Station and Telephone Line port. Each port shall have an associated recording output, 0 dBV, unbalanced and a control activation port, open collector, 24 VDC maximum, 20 mA. Control activation shall occur immediately after communication has been established and deactivate immediately after communication has been terminated.
18