Toastmaster TMHP6 Lighting Instructions, Adjusting Burners, Adjusting Unit For Use On Propane Gas

Models: TMHP6 THMP2 TMHP4

1 16
Download 16 pages 12.9 Kb
Page 5
Image 5
LIGHTING INSTRUCTIONS

LIGHTING INSTRUCTIONS

The appliance is equipped with standing pilots; each pilot is located in front of the burner on Models TMHP2, TMHP6. Pilots should be lighted immediately after the gas is turned on by the manual shutoff valve.

1.

Turn control knobs to "OFF" position.

 

2.

Light pilot with a lighted taper.

1/4”

Flame

 

 

3

The pilot valves are located on the manifold installed

 

 

at the front of the unit behind the front panel. For

 

 

access to the valves

 

4.

Loosen the set screws securing the knobs in

 

 

position, and remove the knobs. Remove the front

 

 

panel, which is attached to the frame with 4 sheet

 

 

metal screws.

 

5.

Turn the adjustment screws on the front of the

 

 

pilot valves. The pilots should be adjusted to blue

 

 

short flame (1/4" high) to have good ignition to the

 

 

burners. Repeat for remaining pilots.

Pilot Valve

6.

If the pilot(s) is out turn off gas, wait 5 minutes and

 

repeat steps (1) through (5).

ADJUSTING BURNERS

7.With control valve for the front burner turned to full "ON" position, close the air shutters to give a soft blue flame having luminous tips and open to a point where the yellow tips disappear, then tighten the locking screws. Repeat this procedure with the remaining burners.

Pilot

Control

IL2426

Valve

Air Shutter

8. Install the front panel to the front of the frame & reconnect and secure the knobs back into position.

ADJUSTING UNIT FOR USE ON PROPANE GAS

Units are shipped with orifices and pressure regulator for operation with natural gas (6" water column). To convert unit from natural to propane gas follow these instructions

1.Set regulator outlet pressure to 10" water column. A 1/8" pipe plug on the manifold can be removed for attaching a pressure gauge. Remove the slotted cover from the pressure regulator and invert the plug. Replace the cover on the regulator and plug on the manifold. Regulator is now set at 10" W.C.

2.Remove natural gas orifices, #46 for all models, and install propane orifices, painted black, (#54 for all models except) located in a bag on the outside of the front panel. In order to remove natural gas orifices:

a.Remove grates and burners.

b.Remove orifices from the manual valves and from fittings on extended gas pipes, replace with the propane orifices.

c.Install burners and grates.

OPERATING PROCEDURE

Each burner will deliver up to 22,000 BTU/HR of heat on all models and is controlled by a manual On/Off valve. The right control knob controls the front burner and the left control knob controls the rear burner on all models. After the pilot is once lit and adjusted, the burners will ignite automatically by turning the control knob to any position between On and Off.

CLEANING THE EXTERIOR (Stainless Steel Only)

The exterior surface can be kept clean and attractive by regularly wiping it with a clean soft cloth. Any discoloration can be removed with a non-abrasive cleaner. The burner grates and trough tray can be removed for cleaning.

MAINTENANCE AND REPAIRS

Contact the factory or one of its representatives or a local service company for service or maintenance if required.