PILOT LIGHTING INSTRUCTIONS
The charbroiler is equipped with standing pilots, and should be lit immediately after the gas is turned on.
1.Turn off main valve to unit.
2.Turn off all knobs and pilot valves and wait 5 minutes to clear gas.
3.Turn on main valve and light all pilots. The best access to the pilot is obtained from the bottom with the grease drawer removed.
4.Adjust pilot light flames as small as possible, but high enough to light burner immediately when burner valve is turned on high.
5.Turn burner knobs to desired setting.
6.To turn burners off, turn knobs off.
SHUTTING DOWN INSTRUCTIONS
Turn the burner valve knobs to the off position to turn burners off.
BURNER IGNITION AND ADJUSTMENT
1.To ignite burners turn burner valve knob to "HI" position.
2.Slowly decrease openings of air shutters on burners to give a soft blue flame having luminous tips, then slowly increase openings to a point where the yellow tips disappear and a hard blue flame is obtained.
PLACING LAVA ROCK ON GRATES (FOR TMLC SERIES)
Open the lava rock bags and place rock evenly on grates. Do not cover the grates with more than two layers of lava rock. DO NOT PUT MORE THAN 5 LBS. OF ROCK PER BURNER!
BURNER OPERATION
Each burner is controlled by an individual