Manual Operation
Note: The valve can be manually operated using the external or internal bleed controls. Refer to Figure 3.
Bleed Screw (external bleed): Turn the bleed screw counterclockwise one full turn or until water begins discharging past the bleed screw threads.
Note: Removing the bleed screw is not required for manual operation, but can be removed to help flush debris from the upper diaphragm area.
To close the valve, turn the bleed screw clockwise until it stops. Do not
Bleed Handle (internal bleed): To open the valve, move the bleed handle coun- terclockwise to the stop. The valve will open as discharge water is routed internally downstream. To close the valve, move the handle clockwise until resistance is felt. Do not
Flow Control Adjustment
The valve is set for maximum flow at the factory. If flow adjustment is required, use the following procedure:
1.While the valve is operating, use a small screwdriver to turn the flow control screw clockwise to decrease flow or counterclockwise to increase flow.
Figure 3 |
Flow Control Screw |
Bleed Screw |
Bleed Handle |
Note: The flow control screw requires approximately seven turns to adjust from maximum to minimum flow.
CAUTION: Do not use the flow control to shut off the valve. Do not force the flow control screw past the end of normal adjustment travel. Damage to the flow control components can occur.
Maintenance Procedure
The Toro Jar Top valve series features a threaded cap nut which enables the valve to be easily disassembled for maintenance. See Figure 4 for the following proce- dure.
1.Shut off the water supply and bleed pressure from the valve using the bleed screw.
2.Turn the cap nut (1) counterclockwise to remove.
3.Remove the cover assembly (2) by gripping the solenoid and gently rocking it back and forth until the assembly is loose and lifts off.
4.Remove the spring (3), diaphragm (4), and divider (5).
5.Turn the
6.Remove the stem assembly (8).
7.Inspect the valve body and internal parts for wear and debris.
8.Clean and reinstall parts into the valve body in reverse order.
Winterization
When winterizing the sprinkler system using compressed air, operate each valve manually from the timer or at the valve for a minimum of one minute, enabling each valve to be thoroughly drained.
Figure 4
1
7 2
3
8 4
5
6
The Toro Promise — Limited One-Year Warranty
The Toro Company and its affiliate, Toro Warranty Company, pursuant to an agreement between them, jointly warrants, to the owner against defects in material and workmanship for a period of one year from the date of purchase.
Neither The Toro Company nor Toro Warranty Company is liable for failure of products not manufactured by them even though such products may be sold or used in conjunction with Toro products.
During such warranty period, we will repair or replace, at our option, any part found to be defective.
Return the defective part to the place of purchase.
Our liability is limited solely to the replacement or repair of defective parts. There are no other express warranties.
This warranty does not apply where equipment is used, or installation is performed, in any manner contrary to Toro’s specifications and instructions, nor where equipment is altered or modified.
NEITHER THE TORO COMPANY NOR TORO WARRANTY COMPANY IS LIABLE FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE USE OF EQUIPMENT, INCLUDING BUT NOT LIMITED TO: VEGETATION LOSS, THE COST OF SUBSTITUTE EQUIPMENT OR SERVICES REQUIRED DURING PERIODS OF MALFUNCTION OR RESULTING
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
ALL IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR USE, ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.
Some states do not allow limitations of how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
© 2007 The Toro Company, Consumer Division |
|
An ISO | Form Number |