5.Once the installation is complete, use a 3/4 inch wrench to screw down the UPS leveling feet located next to the four casters, until the unit is no longer resting on the casters.

6.The UPS generates and can radiate radio-frequency energy during operation. Although RFI noise filters are installed inside of the unit, there is no guarantee that the UPS will not influence some sensitive devices that are operating near by. If such interference is experienced, the UPS should be installed farther away from the affected equipment and/or powered from a different source than that of the affected equipment.

WARNING

THE METAL OF CONDUIT IS NOT AN ACCEPTABLE GROUND.

7.It is the responsibility of the installer of this equipment to provide a suitable disconnect for the Control Panel supplying power to this equipment.

This disconnect must:

Be suitable for the Voltage and Full Load Ampere Rating of all downstream equipment supplied by the Panel;

The supply disconnecting device shall be one of the following types:

Switch-disconnector, with or without fuses, in accordance with IEC 60947-3, utilization category AC-23B or DC-23B

As above, except one that has an auxiliary contact that in all cases causes switching devices to break the load circuit before the opening of the main contacts of the disconnector.

A circuit breaker suitable as an isolation device per IEC 60947-2

Any other switching device in accordance with an IEC product standard that also meets the isolation requirements of IEC 60947-1 and is appropriate for on-load switching of motors or other inductive loads;

Be approved for use as a disconnect for the country in which this equipment is installed. Be provided with a Lock Out Tag Out capability in the Off (Down) position.

8.Allow 5 minutes after power is removed for internal capacitors to fully discharge before attempting to service the unit.

9.The user should provide output over-current protection for hardwired UPS systems. See Specifications section on pages 19 and 22 for the device rating.

10.After ensuring that all power sources are turned off and isolated in accordance with established lockout/tagout procedures, connect the power source wiring of the correct voltage to the input terminals of the UPS.

11.The end user must supply suitable strain relief for the power cord and the cord must extend a distance of 1/2 diameter beyond the clamp.

12.Connect the output terminals of the UPS to the load in line with local wiring regulations. Size the branch circuit conductors in accordance with NEC Table 310.16.

8

1600XP Series Installation and Operation Manual

Page 16
Image 16
Toshiba 1600XP manual Metal of Conduit is not AN Acceptable Ground

1600XP specifications

The Toshiba 1600XP is an advanced multifunction printer that showcases Toshiba's commitment to innovation and reliability in office technology. Designed to meet the demands of modern businesses, the 1600XP integrates several features and technologies that enhance productivity while ensuring high-quality output.

One of the key characteristics of the Toshiba 1600XP is its impressive speed. Capable of printing up to 16 pages per minute, this printer is well-suited for busy work environments where efficiency is paramount. The first print-out time is remarkably fast, minimizing wait times and allowing users to get back to their tasks quickly.

In addition to its speed, the Toshiba 1600XP boasts exceptional print quality. With a high resolution of up to 1200 x 1200 dpi, it produces sharp, clear text and vibrant images, making it ideal for both document printing and professional presentations. The printer uses advanced laser technology, which contributes to consistent and reliable output over time.

The Toshiba 1600XP also integrates advanced scanning capabilities, allowing users to digitize documents with ease. It offers both color and monochrome scanning options, with various file formats available, including PDF and JPEG. The automatic document feeder (ADF) simplifies the scanning process by enabling batch scanning, increasing productivity for users who frequently digitize materials.

Connectivity options are a significant highlight of the Toshiba 1600XP. It comes equipped with USB and Ethernet interfaces, facilitating seamless integration into any office network. For organizations that value mobility, the printer also supports mobile printing solutions, allowing users to print directly from their smartphones or tablets using popular applications.

Energy efficiency is another important aspect of the Toshiba 1600XP. The device is designed to minimize power consumption without compromising performance. Toshiba has incorporated eco-friendly features that help businesses reduce their carbon footprint, making it a practical choice for environmentally conscious organizations.

In summary, the Toshiba 1600XP is a multifunction printer that excels in speed, print quality, and versatility. With its robust scanning capabilities, extensive connectivity options, and energy-efficient design, the 1600XP stands out as an outstanding solution for businesses looking to enhance their document management processes. Whether it's printing, scanning, or copying, the Toshiba 1600XP delivers excellent performance to meet the needs of any fast-paced office environment.