Industrial Division / Houston Motor Plant

Motor Operation Procedure

SHEET NO.

3 of 3

 

 

ISSUED

01/24/96

 

 

SUPERSEDES

NEW

 

 

Fig. 3

 

 

TYPE OF SERVICE

 

 

 

 

 

 

 

SYNC. RPM

FRAME SIZE

STANDARD

SEVERE

VERY SEVERE

 

RANGE

 

DUTY

DUTY

DUTY

 

3600

143T-256T

8 Mos.

4 Mos.

1 Mo.

 

1800 ~ 900

143T-256T

30 Mos.

12 Mos.

4 Mos.

 

Bearing Size

Periodic Grease Amount

 

6205/6206

 

3 Grams

 

 

6207/6208/6305

 

5 Grams

 

 

 

6306

 

10 Grams

 

 

6308/6309

 

20 Grams

 

 

3600

284T-365T

8 Mos.

4 Mos.

1 Mo.

 

1800 ~ 900

284T-365T

24 Mos.

12 Mos.

4 Mos.

 

Bearing Size

Periodic Grease Amount

 

 

6211

 

10 Grams

 

 

 

6309

 

20 Grams

 

 

6310/6312

 

30 Grams

 

 

 

6314

 

50 Grams

 

 

3600

404T-447T

8 Mos.

4 Mos.

1 Mo.

 

1800 ~ 900

404T-447T

18 Mos.

8 Mos.

3 Mos.

 

Bearing Size

Periodic Grease Amount

 

 

6216

 

20 Grams

 

 

6313/NU317

 

30 Grams

 

 

NU318/NU320

 

50 Grams

 

 

6317/6318

 

80 Grams

 

 

6320/6322/6324

 

80 Grams

 

 

NU322/NU324

 

80 Grams

 

 

NU328/NU2228

 

100 Grams

 

NOTES:

1.When relubricating roller bearings divide the monthly service time by two.

2.See Fig. 2 for definitions of Service Conditions.

3.Gram quantity when using a typical low pressure hand grease gun equals (4 pumps = 5 grams)

6.RECOMMENDED GREASES FOR SPECIAL APPLICATIONS

The following greases are recommended for special applicaitons only and should be used only for motors specifically built for such conditions.

 

Minimum Ambient Temp. -60°C

Beacon 325

 

Exxon Corp.

 

Maximum Ambient Temp. 90°C

DOW Corning 44 Exxon Unirex S2

DOW Corning Corp. Exxon Corp.

WARNING: In general it is not recommend to mix greases of different brands. The mixing of different types of thickeners may destroy the composition and physical properties of the grease. In the event that a different grease is required by the end user, the following steps can be taken. Using the instructions for lubrication, open grease outlet and purge the system as much as possible of the old or unwanted grease. Repeat this same operation after 1 week of service. Consult TOSHIBA/HOUSTON Engineering for further recommendations on grease compatibility.

Page 3
Image 3
Toshiba Air Conditioner manual Motor Operation Procedure, Recommended Greases for Special Applications