Phase difference: | The phase difference between the trailing edge | ||||||
| of VD and the trailing edge of HD must be as | ||||||
| shown below. |
|
|
| |||
|
| 1st field | 2nd field | ||||
| VD |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
HD
| t2=1/fH/2 | |||||||
Output signal: | HD,VD negative polarity |
|
|
|
| |||
Level: | 3.5 to | |||||||
| 8.0 to |
|
|
|
| |||
Pulse width: | HD: | 6.36±0.5 micro sec | ||||||
| VD: | 572±5 micro sec |
|
|
|
| ||
Repeat frequency: | fH =15.73426 kHz |
|
|
|
| |||
| fv =2 fH/525 |
|
|
|
|
|
| |
Scanning lines: | 525 lines |
|
|
|
|
|
| |
Output circuit: |
|
|
|
|
|
|
|
|
|
|
|
|
| +9V |
|
| 1k ohm |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| HD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
| VD |
|
|
|
|
|
|
|
|
|
| TD62504F | |||||
Electronic line display or reticle (CS3330BLi ONLY) |
|
|
|
|
|
|
| |
NO. of lines: | 2 horizontal lines, 2 vertical lines | |||||||
Movable range: | Entire monitor screen |
|
|
|
| |||
Line width: | Horizontal line: | 1 scanning line/field | ||||||
| Vertical line: | approx. 0.5 micro sec | ||||||
Polarity : | White(POSI) / black(NEGA) selectable | |||||||
ON/OFF: | switching |
|
|
|
|
|
| |
Electronic line / reticle: | Internal selector switch |
|
|
|
| |||
| (Factory preset is electronic line.) | |||||||
Gamma: | 0.45/1 selectable |
|
|
|
|
|
| |
AGC: | ON/OFF switching |
|
|
|
| |||
| 3 |
|
|
|
|
|
|
|
This specification subjects to change without notice.
D4134992A