Rev 1.0

7.3 Multiple-shutter mode

In the multiple-shutter mode, video is output in sync with a MULTI signal from the external after the end of exposure time.

Valid only when the random trigger shutter mode is ON.

MULTI signals can be input from the camera link I/F CC2.

If exposure is executed several times before MULTI signal input, the images are output superposed. The exposure time is determined by the random trigger shutter mode setting and its determination method. The pulse width must be set to negative polarity and 1H (approximately 53.3μs) to 10 ms.

FVAL is output in sync with the first LVAL after the end of MULTI signal input.

TRIG

 

MULTI

 

A

B

CCD

 

FVAL

 

LVAL

 

DVAL

 

DATA OUT

 

 

A + B

D4134176A

13

Page 14
Image 14
Toshiba CS6940CL specifications Trig Multi CCD Fval Lval Dval Data OUT