Toshiba IK-DF01A instruction manual Line-Lock Control, CAMERA2

Models: IK-DF01A

1 16
Download 16 pages 23.12 Kb
Page 7
Image 7

5-2 Line-Lock Control

Matching the vertical synchronization with the power frequency is called the Line- Lock.

This function is activated when the SYNC menu is selected to LL.

When two or more cameras are switched by the video switcher for viewing by a monitor TV, the vertical sync. phase can be locked with the power frequency, and a stable vertical sync. is obtained without being disturbed at the time of switching.

Video Monitor

VIDEO SWITCHER

CAMERA1

TO AC 24V UL Listed class 2 power supply

CAMERA2

Note :

The camera is synchronized to the power frequency of 60±1Hz covering a normal fluctuation of the power frequency. However, the camera may not cover a large fluctuation caused from the power generated by an engine generator, etc.

It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on. This is normal, because several seconds are required to stabilize the camera against power noise.

Refer to “7. LINE-LOCK PHASE” for adjustment.

- 6 -

Page 7
Image 7
Toshiba IK-DF01A instruction manual Line-Lock Control, CAMERA2