7 3 External Sync

When using the unit with an external sync signal to EXT. SYNC terminal on the rear panel.

When the external sync signal is input, the camera automatically switches its sync from the internal sync to the external sync.

EXT. SYNC input

Operation

 

 

SYNC

External sync with SYNC

 

 

1External sync signal input conditions

SYNC75 unbalanced䋩 䋺 0.6 V (p-p) standard

2 External sync frequency range

(59.94 Hz Setting)

H : 33.716 Hz

35 ppm

 

V : 59.94 Hz

35 ppm

(60 Hz Setting)

H : 33.75 Hz

35 ppm

 

V : 60 Hz 35 ppm

3 Using the unit with external sync signal

Adjust H (Horizontal) phase if necessary to match the output of multiple cameras.

When adjusting H (Horizontal) phase, refer to the item “7.2 (6) SYNC”.

3. 1 H (Horizontal) phase adjustment

Observe the external sync signal and the video signal output

 

waveform of the unit with a dual trace oscilloscope, and adjust

Match

H phase so that the H phases match.

the phase.

 

External Sync. signal

Camera Sync. output

7 4 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H).

1 Setting by 1H

1/1125H to 560/1125H stands for the setting by the 1H and the shutter speed can be set by the 1H.