Toshiba IK-TF9C 1P SR 1 Pulse Trigger Sync Reset, Pulse Trigger SYNC-RESET Picture Output Timing

Models: IK-TF9C

1 32
Download 32 pages 19.94 Kb
Page 25
Image 25

( 2 ) 1P SR (1 Pulse Trigger Sync Reset)

Charge begins to accumulate after the trigger input to CC1 of the DIGITAL terminal, the vertical sync signal is reset and frame images are output.

(2. 1) 1 Pulse Trigger SYNC-RESET Picture Output Timing

Negative polarity mode

Trigger*1

Positive polarity mode

About 1 s

Exposure period*2

Exposure completion

0 to 2H*3

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DVAL

58H (Partial scanning OFF)

56H (Partial scanning 30fps)

78H (Partial scanning 40fps)

*1: Externally input signal

*2: Exposure time is determined by the setting of "7. 2 (1.3) Changing each setting in E.TRG mode".

*3: VD is generated after 0 to 2H following the completion of the exposure period and the video is synchro- nized to this and output.

Note:

When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.