E6581277c
4. Functions in detail
Remote Keypad can be used as remote operation panel (“REMOTE KEYPAD MODE”) or parameter
4.1. Procedure to switch the operation mode
According to the procedure described in “3. Connection and
4.2. “REMOTE KEYPAD MODE”
In “REMOTE KEYPAD MODE”, operation is the same as operation on the panel of the inverter. For details, see instruction manual of the inverter. Data entered through Remote Keypad takes priority over data entered through the inverter’s control panel. However, if Remote Keypad is deactivated by an unexpected event such as an abnormality, the inverter’s input keys remain functional.
4.3. “COPY MODE”
In “COPY MODE”, storing and loading the parameters are permitted. Editing the parameters is not permitted.
| Key | LED indication | Key operation and description | |
|
|
| “chc “ → “init” | When “COPY MODE” is initiated, “chc” is shown in the display |
| ⎯⎯⎯⎯ | window. This is followed by “init” to indicate that the power | ||
|
|
| → ”c0py” | supply is being initialized. Finally, when ready to use the display |
|
|
| shows “”. | |
|
|
|
| |
|
|
|
|
|
|
|
| “c0py” → “c0mp” | < Selecting a desired function > |
|
|
| Select the function with the [SFT] key. Each time the [SFT] key is | |
|
|
| → ”pr0t” → ”clr” | pressed, indication on the display changes from “copy” (copying |
|
|
| function) to “comp” (comparing function), to “prot” (memory | |
| SFT | |||
| → ”f- “ → ”c0py” | protecting function), to “clr” (memory initializing function), to | ||
|
|
| ||
|
|
| “f- ” (Remote Keypad parameter editing function), and finally | |
|
|
|
| back to “copy” again in this order. |