„Changing the setting

Air-dischage direction kit

Installation Manual

„Changing the setting

The setting is changed by using a wired remote controller. (For the details, Refer to “Changing procedure” described below.)

Perform “„Setting the louver lock (Louver position fixing)”.

6 5 1 4 CAUTION

When the ceiling is higher than the specification, the fan control is required. So, in that case, perform the “high ceiling setting” other than the setting described below.

The setting should be performed according to the instructions described on the installation manual attached to the indoor unit.

“Changing procedure”: Change the setting while the device stops.

1 Push – 4 –Manual background + Manual background + Manual backgroundManual background buttons simultaneously for more than 4 sec.

The unit No. displayed at first shows the indoor unit address of the header unit in group control operation. The fan operation of the indoor unit (header unit), selected at this time, is carried out.

2 Every time when UNIT Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background (Left button) is pushed, the No. in the group cotrol operation are displayed in order.

3

4

The fan operation of the indoor unit, selected at this time, is carried out.

Set the CODE No. Manual backgroundManual backgroundManual backgroundManual background by using the TEMP. Manual background / Manual background button.

Set the setting data by pushing TIME Manual background / Manual background buttons for the TIME setting.

3-way air flow ...................... Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

2-way air flow ...................... Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

3

6 5 1 4

2

5 Push the Manual background button. (The setting completes if the setting data are displayed.)

When changing the setting of other indoor unit in the group control operation, return to 2.

6 Pushing the Manual background button enters to the normal stop status.

EN

– 4 –

4-EN

Page 5