Operating Environment
•Please use the
Operation:
Storage:
•Avoid installation locations that may be subjected to large shocks or vibrations.
•Avoid installation locations that may be subjected to rapid changes in temperature or humidity.
Installation • Wiring
•Do not touch charged parts of the drive such as the terminal block while the drive’s CHARGE lamp is lit. A charge will still be present in the drive’s internal electrolytic capacitors, and therefore touching these areas may result in an electrical shock. Always turn all drive input power supplies OFF, and wait at least 5 minutes after the CHARGE lamp has gone out before connecting communication cables or motor wiring.
•Proper ground connections are vital for both safety and signal reliability reasons. For proper grounding procedures, please refer to the section in this manual pertaining to grounding (section 4).
•Route all communication cables separate from the drive’s input/output power wiring.
•To avoid the possibility of electric shock due to leakage currents, always ground the drive’s E/GND terminal and the motor. To avoid misoperation, do not connect the
•When making connections between the
•For further
Other Precautions
•Internal drive EEPROMs have a limited life span of write cycles. Observe all precautions contained in this manual and Toshiba manuals regarding which drive registers safely may and may not be repetitively written to.
•Do not touch or insert a rod or any other item into the
•Commission the disposal of the
•Because the
3