Trane Air Filtration System User’s Information, Components Of The Trane Cleaneffectstm, 4 5 3 3

Models: Air Filtration System

1 8
Download 8 pages 43.22 Kb
Page 2
Image 2
User’s Information

User’s Information

Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTSTM

4

Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTSTM5

3

3

2

6

1

2

3

 

 

 

 

1

Fig. 1

1)Pre-filter- Traps large particles such as hair and lint before they can enter the cell section.

2)Field Charger - Charges the contaminants. Only to be serviced by a qualified technician.

3)Collection Cell (2) - Removes and collects very small impurities from the air.

4)Cabinet - Mounts between the furnace or air handler and return air duct work and houses the collection cells, field charger and pre-filter.

5)Power Door - The solid state power supply components that convert the 24 Volt AC to the high-voltage, direct current required to power the field charger and cells. Allows access to the collection cells, field charger and pre- filter.

6)24 Volt Power Cable

DISPLAY FEATURES

The air cleaner display (Fig. 2) has the following functions:

LED and Pre-filter lights display the operating status of the air cleaner, indicating when to clean the pre-filter or collection cells.

The LED display is also used in the set-up mode, see page 5.

Fig. 2

32-5035-02

2

Page 2
Image 2
Trane Air Filtration System manual User’s Information, Components Of The Trane Cleaneffectstm, Display Features, 4 5 3 3