PRE-FILTER CLEANING:

not remove the door until all lights are off.

Disconnect the power cable, if required, and place the door in a secure location.

Rotate the two latches and remove the door.

PRE-FILTER CLEANING:

The pre-filter can be vacuumed (recommended) or washed clean.

It is recommended the filter be vacuumed outside the home to ensure particles on the filter are not re-introduced into the air. Persons highly sensitive to the collected particles should wear appropriate respiratory protection while cleaning the filter.

The pre-filter can be washed using low pressure water spray, such as a sink sprayer or garden hose. The pre-filter should be completely dry before re-installing. Re-install the pre-filter noting the airflow direction as indicated on the filter.

NOTE: Do not replace the plastic pre-filter with a metal type pre-filter. A metal pre-filter will cause reduction in efficiency and potential failure of the system electronics.

COLLECTION CELL CLEANING

Remove both collection cells from the system housing. The cells can be cleaned either by vacuuming (recommended method) or by washing.

VACUUM CLEANING

Using the wand attachment, vacuum both sides of the collection cells until they are clean

It is recommended the filter be vacuumed outside the home to ensure particles on the filter are not re-introduced into the air. Persons highly sensitive to the collected particles should wear appropriate respiratory protection while cleaning the filter.

User’s Information

WASHING

Use low-pressure water spray, such as a sink sprayer or garden hose to clean the cells. Stubborn residue like tobacco smoke may require warm water to be removed.

Do NOT use soap or detergent in cleaning the collection cells.

Do NOT immerse the cells completely in water.

Do NOT place the cells into a dishwasher to clean.

Slightly tap the collection cells to remove water retained in the filter. Allow the collection cells to dry completely before re-installing.

Re-install the collection cells. With the handles facing the front of the unit, align the slot on the cell with the tab on the cabinet. Fold the collection cell handles flat once installation is complete.

RE-INSTALLING THE POWER DOOR

Install the door by positioning tabs inside of the frame and rotating the door into place. Rotate the two latches to secure the door. Plug in the power cable if removed. Turn on power to the unit by pressing and releasing the power button.

NOTE: The first green LED will be on but will not flash for the first 10 minutes the indoor fan is operating. This is a drying cycle for the pre- filter and collection cells.

RESET THE FILTER TIMERS

To reset the pre-filter timer, press and hold the RESET button until the pre-filter LED turns off. (1 to 2 seconds)

To reset the collection cell timer, press and continue to hold the RESET button until the collection cell LED’s turn off. (4 to 5 seconds)