Trane EXWA, WPWD, GSWD manual Troubleshooting, Hazardous Service Procedures, General Operation

Models: GSWD WPWD EXWA

1 31
Download 31 pages 50.77 Kb
Page 27
Image 27

Troubleshooting

WARNING

Hazardous Service

Procedures!

The maintenance and trouble shooting procedures recommend- ed in this section of the manual could result in exposure to electri- cal, mechanical or other potential safety hazards. Always refer to the safety warnings provided throughout this manual concern- ing these procedures. When possi- ble, disconnect all electrical power including remote discon- nects before servicing. Follow proper lockout/tagout procedures to ensure the power can not be in- advertently energized. When nec- essary to work with live electrical components, have a qualified li- censed electrician or other indi- vidual who has been trained in handling live electrical compo- nents per these tasks. Failure to follow all of the recommended safety warnings provided, could result in death or serious injury.

Preliminary Trouble Inspection If operational difficulties are encoun- tered, be sure to perform the prelimi- nary checks before referring to the troubleshooting chart on page 28.

Verify that the unit is receiving elec- tric supply power.

Ensure that the fuses in the fused disconnect are intact.

After completing the preliminary checks, inspect the unit for other obvi- ous problems such as leaking connec- tion, broken or disconnected wires, etc. If everything appears to be in or- der, but the unit still fails to operate properly, refer to the troubleshooting chart on page 28.

General Operation

The standard model is designed for in- door installation. When the unit is in- stalled in an unconditioned space, the unit may not start in cool weather (ap- proximately 45°F). It may then be nec- essary to start the unit in the cooling mode for three to five minutes. The unit may then be shut-off (there will be a two minute time-out of the unit), and restarted in the heating mode. The freeze protection thermostat should also be checked as it may be adversely affected by ambient temperature. Like any other type of mechanical equipment, the unit performs best when it is well maintained.

Operation with a Conventional Thermostat

The unit is equipped with safety con- trols, including high pressure control, low pressure control and a freeze pro- tection thermostat, set to shut off the compressor under abnormal tempera- ture or pressure conditions. If the safe- ties shut off the compressor, a lockout relay prevents short cycling from the abnormal condition. When conditions are corrected, the lockout control can be reset by setting the thermostat sys- tem switch to OFF wait a few minutes for the system pressure to equalize, and then return to HEAT or COOL. If the condition continues, an authorized service person should check out the unit.

WSHP-SVX02A-EN

27

Page 27
Image 27
Trane EXWA Troubleshooting, Hazardous Service Procedures, General Operation, Operation with a Conventional Thermostat

GSWD, WPWD, EXWA specifications

Trane is a leading provider of heating, ventilation, and air conditioning (HVAC) systems, and their GSWD, WPWD, and EXWA series are some of the most innovative and efficient products available in the market. These product lines are designed to meet diverse HVAC needs by offering distinctive features, cutting-edge technologies, and remarkable performance characteristics.

The Trane GSWD series is known for its robust design and versatility, making it ideal for various commercial applications. One of the standout features of GSWD units is their modular design, which allows for easy installation and scalability. They are equipped with high-efficiency compressors that contribute to energy savings while ensuring optimal cooling performance. The GSWD series also includes advanced control systems, which enable precise temperature management and system monitoring, leading to improved comfort and reduced operating costs.

On the other hand, the Trane WPWD series focuses on delivering exceptional water-source heat pump solutions. These units stand out for their ability to harness energy from renewable water sources, thereby offering environmentally friendly operation. With a focus on energy efficiency, the WPWD models utilize variable-speed technology that adjusts the compressor's output based on demand, resulting in significant energy savings. Additionally, these models are designed to operate quietly, which enhances the overall comfort of indoor environments.

The EXWA series represents Trane's commitment to innovation in air-to-water heat pump technology. Featuring advanced inverter technology, the EXWA units can efficiently operate across a wide range of environmental conditions. This allows them to deliver reliable heating and cooling performance without compromising efficiency. The EXWA series also emphasizes ease of maintenance, with accessible components designed for quick servicing and reduced downtime.

All three series prioritize user-friendly interfaces, enabling easy system operation and monitoring. Trane incorporates smart technology that promotes connectivity and integration with building management systems, making it easier for operators to manage HVAC systems efficiently.

In summary, the Trane GSWD, WPWD, and EXWA series provide innovative HVAC solutions characterized by energy efficiency, advanced technology, and user-friendly features. Their unique designs cater to various applications, ensuring that they meet modern building requirements while being environmentally responsible and cost-effective. Trane continues to lead the way in HVAC technology, setting benchmarks for performance, reliability, and sustainability in the industry.