User Guide
User Settings
User Settings allow the user to customize various settings on the 624 control. To access User Settings simply press the Menu button once and “User Settings” will be displayed. To enter the User Settings menu, press the Select button, then use the Next button to navigate through the options below. The default setting will be shown in brackets. After each selection press the Done button to save changes.
|
| Thermostat | |
Setting | Range |
| Description |
Temperature Scale | [Fahrenheit], Celsius |
| Select the temperature display scale |
Cooling RH Setpoint | 30% - 60% [50%] |
| Select the desired indoor relative humidity during cooling mode. Dehu- |
|
|
| midification must be enabled in the Installer Settings for this option to be |
|
|
| available. |
Smart Continuous Fan | Yes, [No] |
| If yes is selected, continuous fan mode is disabled when indoor humidity |
|
|
| exceeds the Cooling RH Setpoint |
Continuous Fan Airflow | 35% - 100% [50%] |
| Select the desired fan speed when the Fan Mode selected is Continuous |
|
|
| (variable speed blower required) |
Fan Circulate On Time | 1 - 59 minutes, [Off] |
| Select the desired amount of time the fan will cycle per hour when the Fan |
|
|
| Mode selected is Circ |
Local Schedule Enable | [Yes], No |
| Select whether scheduling will be enabled or disabled |
Max Heat Setpoint | 55 - [90] Degrees |
| Select the highest heating setpoint allowed |
Min Cooling Setpoint | [60] - 99 Degrees |
| Select the lowest cooling setpoint allowed |
H/C Delta | [3] - 15 Degrees |
| Select the minimum deadband between Heating and Cooling setpoints |
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
|
|
| Energy Savings Mode | |
Setting |
| Range |
| Description |
ESM Heat Setpoint | 55 | - 90 degrees [62] |
| Select the desired Heating Setpoint when ESM (Energy Savings Mode) is |
|
|
|
| selected |
ESM Cooling Setpoint | 60 | - 99 Degrees [85] |
| Select the desired Cooling Setpoint when ESM (Energy Savings Mode) is |
|
|
|
| selected |
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
|
| Display |
Setting | Range | Description |
Screen Timeout | [0] - 90 Seconds | Select how long after the last button press before the screen timeouts to a |
|
| minimized screen |
Backlight Timeout | 0 - 90 Seconds [20] | Select how long after the last button press before the backlight dims |
Backlight On Percent | 0 - [100] Percent | Select the screen brightness when the backlight is lit |
Backlight Off Percent | [0] - 100 Percent | Select the screen brightness when the backlight timeout expires |
Buzzer Enable | [Yes], No | Select whether button presses are audible |
Security | [Unlocked], Display Lock, Guest | Select security level |
| Access | • Unlocked - Enables selection of all menus and settings |
|
| • Display Lock - Disables selection of all menus and settings |
|
| • Guest Access - Disables selection of all menus and settings except the |
|
| following: Raise or lower heating or cooling setpoint +/- 5 degrees and |
|
| change system mode |
|
| Note: When Display Lock or Guest Lock is selected a lock icon will appear |
|
| next to the up arrow. |
|
| Note: To disable Display Lock or Guest Access, press and hold the up |
|
| and down arrows until the lock icon disappears. |
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
4