User Settings

User Guide

User Settings

User Settings allow the user to customize various settings on the 624 control. To access User Settings simply press the Menu button once and “User Settings” will be displayed. To enter the User Settings menu, press the Select button, then use the Next button to navigate through the options below. The default setting will be shown in brackets. After each selection press the Done button to save changes.

 

 

Thermostat

Setting

Range

 

Description

Temperature Scale

[Fahrenheit], Celsius

 

Select the temperature display scale

Cooling RH Setpoint

30% - 60% [50%]

 

Select the desired indoor relative humidity during cooling mode. Dehu-

 

 

 

midification must be enabled in the Installer Settings for this option to be

 

 

 

available.

Smart Continuous Fan

Yes, [No]

 

If yes is selected, continuous fan mode is disabled when indoor humidity

 

 

 

exceeds the Cooling RH Setpoint

Continuous Fan Airflow

35% - 100% [50%]

 

Select the desired fan speed when the Fan Mode selected is Continuous

 

 

 

(variable speed blower required)

Fan Circulate On Time

1 - 59 minutes, [Off]

 

Select the desired amount of time the fan will cycle per hour when the Fan

 

 

 

Mode selected is Circ

Local Schedule Enable

[Yes], No

 

Select whether scheduling will be enabled or disabled

Max Heat Setpoint

55 - [90] Degrees

 

Select the highest heating setpoint allowed

Min Cooling Setpoint

[60] - 99 Degrees

 

Select the lowest cooling setpoint allowed

H/C Delta

[3] - 15 Degrees

 

Select the minimum deadband between Heating and Cooling setpoints

Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.

 

 

 

Energy Savings Mode

Setting

 

Range

 

Description

ESM Heat Setpoint

55

- 90 degrees [62]

 

Select the desired Heating Setpoint when ESM (Energy Savings Mode) is

 

 

 

 

selected

ESM Cooling Setpoint

60

- 99 Degrees [85]

 

Select the desired Cooling Setpoint when ESM (Energy Savings Mode) is

 

 

 

 

selected

Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.

 

 

Display

Setting

Range

Description

Screen Timeout

[0] - 90 Seconds

Select how long after the last button press before the screen timeouts to a

 

 

minimized screen

Backlight Timeout

0 - 90 Seconds [20]

Select how long after the last button press before the backlight dims

Backlight On Percent

0 - [100] Percent

Select the screen brightness when the backlight is lit

Backlight Off Percent

[0] - 100 Percent

Select the screen brightness when the backlight timeout expires

Buzzer Enable

[Yes], No

Select whether button presses are audible

Security

[Unlocked], Display Lock, Guest

Select security level

 

Access

• Unlocked - Enables selection of all menus and settings

 

 

• Display Lock - Disables selection of all menus and settings

 

 

• Guest Access - Disables selection of all menus and settings except the

 

 

following: Raise or lower heating or cooling setpoint +/- 5 degrees and

 

 

change system mode

 

 

Note: When Display Lock or Guest Lock is selected a lock icon will appear

 

 

next to the up arrow.

 

 

Note: To disable Display Lock or Guest Access, press and hold the up

 

 

and down arrows until the lock icon disappears.

Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.