Transition Networks CFETF1011-205 Installation -- Continued, Troubleshooting, CFETF10xx-205

Models: CFETF1011-205

1 8
Download 8 pages 28.78 Kb
Page 4
Image 4
Installation -- Continued

CFETF10xx-205

Installation -- Continued

Set the AutoCross™ Jumper

When the AutoCross feature is activated, it allows either straight-through or crossover cables to be used when connecting to 100Base-TX devices. AutoCross determines the characteristics of the connection and automatically configures the unit to link up, regardless of the cable configuration.

The jumper is located on the circuit board labeled “D” and “E”.

Use small needle-nose pliers to remove and position the jumper.

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:

1.

Is the PWR LED on the media converter illuminated?

 

NO

 

• Is the media converter installed properly in the chassis?

 

• Is the power cord properly installed in the chassis and at the external

 

power source?

 

• Does the external power source provide power?

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

Disable

Either straight-through or crossover

 

twisted-pair copper cable must be

 

installed, according to the site

 

requirements.

Enable

The media converter connects

 

automatically to either straight-through or

 

crossover twisted-pair copper cable.

DSet the AutoCross™ JumperTroubleshootingInstall the media converterManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background E Disable AutoCross

D Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background E Enable AutoCross

 

YES

 

• Proceed to step 2.

2.

Is the LKC LED on the media converter illuminated?

 

NO

 

• Check the twisted-pair cables for proper connection.

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

 

YES

 

• Proceed to step 3.

NOTE: AutoCross is enabled by default.” Transition networks recommends leaving the jumper in the “enable” position.

Install the media converter

CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the CFETF10xx-205 media converter. Failure to observe this caution could result in damage to or failure of, the media converter.

1.Carefully slide the media converter into the slot, aligning it with the slot guides.

2.Ensure that the converter is firmly seated into the slot.

3.Push in and rotate the attached panel fastener screw clockwise to secure the converter to the chassis.

Point System Chassis

Panel Fastener

Slot

Media Converter

3.

Is the LKF LED on the media converter illuminated?

 

NO

 

• Check the fiber cables for proper connection.

 

• Verify that the TX and RX cables on the media converter are

 

connected to the RX and TX ports, respectively, on the other device.

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

 

YES

 

• Proceed to step 4.

4.

Is the RXC LED on the media converter flashing?

 

NO

 

• If there is no activity on the 100Base-TX port, proceed to step 5.

 

• If there is activity on the 100Base-TX port, disconnect and reconnect

 

the 100Base-TX cable to restart the initialization process.

 

• Restart the workstation to restart the initialization process.

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

 

YES

 

• Proceed to step 5.

5.

Is the RXF LED on the media converter flashing?

 

NO

 

• If there is activity on the 100Base-FX port, disconnect and reconnect

 

the 100Base-FX cable to restart the initialization process.

 

• Verify that the TX and RX cables on the media converter are

 

connected to the RX and TX ports, respectively, on the other device.

 

• Restart the workstation to restart the initialization process.

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

 

YES

 

• Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

4

24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

13

Page 4
Image 4
Transition Networks CFETF1011-205 Installation -- Continued, Troubleshooting, Set the AutoCross Jumper, CFETF10xx-205