Transition Networks CFETF1011-205 specifications Technical Specifications, Connect the Fiber Cable

Models: CFETF1011-205

1 8
Download 8 pages 28.78 Kb
Page 5
Image 5
Technical Specifications

CFETF10xx-205

Technical Specifications

For use with Transition Networks Model CFETF10xx-205 or equivalent.

Standards

IEEE 802.3™

 

Data Rate

100 Mb/s

 

Dimensions

3.4" x 5.0" x 0.87" (86 x 185 x 22 mm)

Weight

3 oz (91 g) (approximate)

Power Consumption

3.5 watts, 200 mA @ 13.9 VDC

MTBF

382,956 hours (MIL217F2 V5.0) (MIL-HDBK-217F)

 

1,456,260 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32 to 140°F )

 

Storage Temp:

-20 to 85°C (-4 to 185°F )

 

Humidity

5 to 95%, non condensing

 

Altitude

0 to 10,000 feet

Warranty

Lifetime

 

*Manufacturer’s rated ambient temperature: Tmra range for the CFETF10xx-205 media converter depends on the physical characteristics and the installation configuration of the PointSystem™ chassis, in which the module will be installed.

The information in this user’s guide is subject to change. For the most up-to-date information on the CFETF10xx-205 media converter, view the user’s guide on- line at: www.transition.com

This product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.3 oz (91 g) (approximate)

CAUTION: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments.

CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

Installation -- Continued

Connect the Fiber Cable

1.Locate a 100Base-FX compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends.

2.Connect the fiber cables to the CFETF10xx-205 media converter as described:

Connect the male TX cable connector to the female TX port.

Connect the male RX cable connector to the female RX port.

3.Connect the fiber cables to the other device (another media converter, hub, etc.) as described:

Connect the male TX cable connector to the female RX port.

Connect the male RX cable connector to the female TX port.

Connect fiber cable

Connect fiber cable

to media converter

to other device

as shown.

(media converter,

 

 

 

 

 

hub, etc.) as shown

RX

 

 

 

 

 

 

 

 

RX

 

 

 

 

 

 

 

TX

 

 

 

 

 

 

 

 

 

 

TX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect the Twisted-Pair Copper Cable

1.Locate or build 100Base-TX compliant cables, with male RJ-45 connectors installed at both ends.

2.Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the CFETF10xx-205 media converter.

3.Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).

Point System Chassis

RJ-45 Port

Media ConverterRJ-45 Port

On other device

(workstation, switch, etc.)

12

24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

5

Page 5
Image 5
Transition Networks CFETF1011-205 Technical Specifications, Connect the Fiber Cable, Connect the Twisted-Pair Copper Cable