MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards | ANSI X3T12 FDDI |
|
Case dimensions | 4.7" x 3.0" x 1.0" | (119mm x 76mm x 25mm) |
Environment | Temperature: | |
| Humidity | |
| Altitude |
|
Lifetime
Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 12VDC @1.5 A).
TN PN | Requirement | Location |
3507 | 240 volts, 50 hertz | United Kingdom |
3342 | 230 volts, 50 hertz | Europe |
3340 | 120 volts, 60 hertz | USA/Canada/Mexico |
3346 | 100 volts, | Japan |
3511 | 240 volts, 50 hertz | Australia |
3537 | (with power cord: 3522) | South Africa |
Minneapolis, MN 55344 USA
FDDI/CDDI Media Converters
USER’S GUIDE
The TRANSITION Networks Ethernet™ CDDI to FDDI media converters connect CDDI unshielded twisted pair cable to FDDI multimode OR to FDDI singlemode
NOTE: This product also can be powered by the Transition Networks
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
FD-CD-01
Provides an
| MDI |
| |
Input |
| CDDI | |
12V DC | FDDI to CDDI |
| FDDI |
UTP
Multimode Fiber
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den
Compliance Information
UL Listed
FD-CD-01(SM)
Provides an
| MDI |
| |
Input |
| CDDI | |
12V DC | FDDI to CDDI | FDDI | Singlemode |
UTP
Singlemode Fiber
Status LEDs on the connector side of the media converters provide the following information:
FCC Regulations
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Copyright Restrictions
Power Illuminated green LED indicates connection to external AC power.
SDF Signal Detect/Fiber: Steady green LED indicates fiber port is connected to device.
SDC Signal Detect/Copper: Steady green LED indicates
RXC Receive/Copper: Flashing green LED indicates packets are seen on
RXF Receive/Fiber: Flashing green LED indicates packets are seen on fiber port.
CDDI Connector
TX RX Power
SDF
SDC
| RXC |
|
|
|
|
| RXF |
|
|
|
|
Fiber |
| ||||
|
| ||||
| UTP/STP Power |
FDDI Connector
SDF
SDC
RXC
RXF
© 1997 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
NOTE: Since the FDDI/CDDI protocol passes a “token” across the entire FDDI/CDDI ring, the RXC/RXF LEDs are continuously illuminated during normal operation.
All registered trademarks and trademarks are the property of their respective owners. | 33025.B |