Tri-M Systems HE104 technical manual Output Power Connector

Models: HE104

1 32
Download 32 pages 24.06 Kb
Page 10
Image 10

23 June 2005

HE104MAN-V8 Manual

2.3.2 Output Power Connector

Output power is available for non-PC/104 use via connector CN2.

-Terminal 1: +5VDC output

-Terminal 2: Common

-Terminal 3: +12VDC

-Terminal 4: -12VDC output (optional)

-Terminal 5: -5VDC output (optional)

2.3.3Battery Power Connector (Optional)

Batteries are connected to the screw terminal block, CN3. The HE104 accepts DC battery voltages in the range of 6.5V to 40DVC through the Battery Power Connector. Two external signals can be connected to the battery terminal block for use by add-on modules plugged into the mezzanine header connectors. Connect to the HE104 Battery Terminal Block as follows:

-Terminal 1: Common of battery

-Terminal 2: Positive Battery Terminal

-Terminal 3: External signal 1

-Terminal 4: External signal 2

Note: When Optional Plug-IN Boost regulator (VR3) is ordered, batteries or external signals cannot be connected to CN3. See section 2.3.4

2.3.4 Onboard PC “Boost” Adaption (Optional)

An optional converter Boost pump (model NMH05XXS, XX=output voltage, + 5V, +9V, +12V, +15V) can be installed in location VR3 to provide custom output voltages. The NMH charge pumps have an isolated positive and negative output and a maximum 2-watt capacity. A minimum load of 10 percent is required for proper operation. By connecting the charge pump to other voltages, the user can create more or less supplies, as well as elevated and negative voltages (i.e.: The charge pump “0V” is not connected to the HE104 common).

-Terminal 1: Common of battery

-Terminal 2: -V output

-Terminal 3: 0V

-Terminal 4: +V output