Let DIOp =D0

‘next bit of command

Pulsout CLK.2

‘Activate the LTC1594

Low CS1

‘Get ready for input from LTC 1594

Input DIO

 

Pulsout CLK.2

‘Dummy statement for delay

Input DIO

‘Sampling requires two clocks

Pulsout CLK.2

 

Let AD = 0

‘Clear old ADC result.

For Adbits = 1 to 13

‘Get null bit + 12 data bits.

Pulsout CLK.2

‘Clock next data bit in.

Let AD = AD*2 +DIOp

‘Shift AD left, add new data bit.

Next Adbits

‘Get next data bit.

High CS1

‘Turn off the ADC

Return

‘Return to program.

‘D1 = 1, D0 = 0 channel 2 input, monitors input voltage of battery regulator ‘D1 = 1, D0 =1 channel 3 input, monitors battery charging current

‘Note: channel 0 is usually jumpered to CN3 term2 for monitoring battery voltage

‘Note: channel 2 tracks main power input when greater than battery voltage

‘Note: channel 2 approx. 0.6V less than battery voltage when main input less than battery voltage.

SYMBOL AD = w1 SYMBOL Chrg Time = w2 SYMBOL Batt_Peak = w3 SYMBOL TCnt =b8 SYMBOL Batt_V = w5 SYMBOL sglDif = 1 SYMBOL msbf = 1 SYMBOL AO1_LVL = 5 SYMBOL BattV_Max = 1100 SYMBOL Chrg_Time_Max =10800

SYMBOL Neg_DeltaV = 8

SYMBOL Trickle_LVL = 0 SYMBOL BattV_Min = 740

Main Loop

Init:

12-bit ADC conversion result

16-bit timer

Peak voltage detected

Single-ended, two-channel mode. Output 0s after data transfer is complete. Maximum current level (50 = 1A 75 = 1.5A) Maximum battery pack charge voltage Maximum battery charging time (10,800 = 3hr.)

AD convertor points for –deltaV (74pt/V IE 0.2V=18pts).

Trickle Charge Level (12 =.25A) See below: Minimum battery voltage (10V)

Low PSU_OnOff

‘Turn PSU on

 

 

 

 

 

 