Tricity Bendix TBG700 user manual Gas Connection, When The Hob Is First Installed

Models: TBG700

1 32
Download 32 pages 60.19 Kb
Page 17
Image 17
Gas Connection

Gas Connection

Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel or copper. The connection should be suitable for connecting to R 1/2 (1/2 BSP male thread).

When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation.

Ensure that the main connection pipe does not exert any strain on the hob.

WHEN THE HOB IS FIRST INSTALLED

Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory.

On the end of the shaft, which includes the GJ 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force.

It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe.

Failure to ensure the correct assembly will cause leakage of gas.

FO

0814

FO 0264

A)End of shaft with nut

B)Washer

C)Elbow

17

Page 17
Image 17
Tricity Bendix TBG700 user manual Gas Connection, When The Hob Is First Installed