Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

1)Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

1)Re-ignite the burner and set to MIN.

2)Remove the control knob.

3) To adjust, use a thin bladed

 

screwdriver and turn the adjustment

 

screw (see diagram) until the flame

 

is steady and does not extinguish,

 

when the knob is turned from MIN

 

to MAX. Repeat this procedure for

Minimum adjustment screw

all burners.

 

Pressure Testing

The pressure testing must becarried out on the burners.

Proceed as follows:

1)Remove the pan supports and the burner caps and crowns.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar.

4)Turn off the burner supplies.

26

Page 26
Image 26
Tricity Bendix TBG700 user manual Commissioning, Pressure Testing