OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

Ignition HT Spark

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference.

Spark Generator

Ispra Control's BF 50046 - 230-240V

0.6 YA T 120

Spark Gap

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Left Burner (semi rapid)

 

 

 

 

 

 

 

 

 

 

Heat Input

 

2.0 kW (6824 BTU/HR)

Rear Right Burner (semi rapid)

 

 

 

 

 

 

 

 

 

Heat Input

 

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

 

 

 

 

 

 

 

 

 

 

Heat Input

3.0 kW Natural Gas (10236 BTU/HR)

Front Right Burner (auxiliary)

 

 

 

 

 

2.8 kW L.P.G. (9554 BTU/HR)

Heat Input

 

1.0 kW (3412 BTU/HR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFTYPE

GAS

 

CHARACTERISTICS

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

 

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURALGAS

20mbar

 

3

 

 

 

 

 

 

 

 

 

 

 

 

=VALUE37.78 MJ/m 50.7-WsMJ/ m

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

3

POWER

kW

3.0

0.65

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.057

0.190

 

0.038

0.095

0.028

 

 

 

 

 

 

 

NOZZLE REFERENCE

119

Adjust.

96

 

Adjust.

70

Adjust.

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GASLPG

mbar30/37-28

 

MJ/Kg49.92=VALUE

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

POWER

kW

2.8

0.65

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

g/h

202

43.5

144

 

29

72

21,5

 

 

 

 

 

 

 

NOZZLE REFERENCE

86

40

71

 

32

50

28

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid40

Aeration adjustment none

CLASS APPLIANCE: 3

APPLIANCE

CATEGORY: II2H3+

APPLIANCE

GAS SUPPLY: Natural gas G20 / 20mbar

12

Page 12
Image 12