Fault Finding

Fault Finding

Preliminary Electrical Systems Check

PLUG (with cover removed)

SOCKET

 

(face view)

Brown Blue Green Yellow

Blue

BrownGreen Yellow

START

Isolate appliance and carry out:

A:Earth Continuity check.

Earth Wire Green/Yellow

Neutral Wire

Blue

(

)

 

FUSE

E(Preliminary Electrical Systems Check)

NL

NO

YES

Carry out:

 

Carry out:

 

Electricity supply

 

D: Resistance to

 

 

should now be

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK -

Appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point

to earth pin on plug. Resistance should be less than 0.1 Ω (Ohm), check all earth

wires for continuity and all contacts clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on Ω (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on Ω (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.