Tricity Bendix TM 560 installation instructions Electrical Connections

Models: TM 560

1 14
Download 14 pages 63.62 Kb
Page 6
Image 6

Electrical Connections

WARNING:THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

If the plug that is fitted to your appliance is not suitable for your socket outlet, it must be cut off, and the appropriate plug fitted.

Remove the fuse from the cut off plug. The cut off plug should then be disposed of to prevent the hazard of electric shocks, in case it should be plugged into a 13 Amp socket in another part of your home.

 

GREEN & YELLOW

 

IMPORTANT

 

13 AMP FUSE

The wires in the mains

 

 

 

 

 

 

 

 

lead are coloured in

 

 

13 AMP

accordance with the fol-

 

 

lowing code:

 

 

 

Green and Yellow - Earth

 

 

BROWN

Blue - Neutral

 

 

Brown - Live

 

BLUE

 

P0329

CORD CLAMP

 

If you fit your own plug, the colours of the wires in the mains lead of your appliance may not correspond with the markings iden- tifying the terminals in your plug.

To fit the plug, proceed as follows:

Connect the green and yellow (earth) wire to the ter- minal in the plug which is marked with the letter «E»

or the earth symbol

, or coloured green and yellow.

Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter «N» or coloured black.

Connect the brown (live) wire to the terminal in the plug which is marked with the letter «L» or coloured red.

The plug moulded on to the lead incorporates a fuse. For replacement, use a 13 Amp BS1362 fuse. Only ASTA or BSI approved fuses should be used.

The plug must not be used if the fuse cover/carrier is lost. The cover/carrier is indicated by the coloured insert at the base of the plug.

A replacement cover/carrier must be obtained from your local Tricity Bendix Service Centre.

There is a list of these at the end of this instruction book.

Avoid connecting the tumble dryer to the same socket as your washing machine (or any other appliance) by means of an adaptor. Have an extra socket installed if necessary, by a qualified electrician.

Note

Installation, and, in particular, connection to the elec- tric mains and to the discharge vent must be carried out by a competent person or qualified electricians.

Please ensure that when the appliance is installed it is easily accessible for the engineer, in the event of a breakdown.

6

Page 6
Image 6
Tricity Bendix TM 560 installation instructions Electrical Connections