Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS systems. Failure to follow these warnings will void your warranty.

UPS Location Warnings

Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.

For best performance, keep the indoor temperature between 32° F and 104° F (between 0° C and 40° C).

Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.

Do not modify the UPS’s plug, and do not use an adapter that would eliminate the UPS’s ground connection.

Do not use extension cords between the UPS and outlet. Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet.

If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.

Equipment Connection Warning

Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Do not connect surge suppressors or extension cords to the output of your UPS. This might damage your UPS and will void both the surge suppressor and UPS warranties.

Battery Warnings

Your UPS does not require routine maintenance. Do not open your UPS except to replace batteries. There are no user-serviceable parts inside.

Battery replacement should be performed by qualified service personnel. Because the batteries present a risk of electrical shock and burn from high short-circuit current, service personnel should observe proper precautions. Use tools with insulated handles, remove all metal hand jewelry and when possible work with only one hand to reduce the danger of shock. Replace the existing batteries with an equal number of new batteries of the same type. Do not open the sealed lead-acid batteries. Do not short or bridge the battery terminals with any object.

The UPS batteries are recyclable. Refer to local codes for disposal require- ments or in the USA only call 1-800-SAV-LEAD (1-800-728-5323) for complete recycling information. Do not dispose of the batteries in a fire.

The UPS contains its own energy source (battery). The output terminals may be live even when the UPS is not connected to an AC supply.

Only connect Tripp Lite battery packs of the correct voltage to your UPS’s external battery connectors.

Do not connect or disconnect external battery packs while the UPS is operating from battery.

Do not operate your UPS without batteries.