PDU Selector Guide (Input/Output)
Choose by matching power source input to PDU output.
Step 1 |
| |
Choose Power Source Input | ||
Receptacle Type | Voltage | Current |
15A | ||
20A | ||
20A | ||
30A | ||
20A | ||
30A | ||
C13 | Varies | Varies |
C19 | Varies | Varies |
VARIES | Varies | Varies |
(User provides |
|
|
C19 or C13, |
|
|
depending on |
|
|
model, to the input |
|
|
plug of their choice.) |
|
|
Step 2
Choose PDU Output
| Basic PDUs | Metered PDUs | Switched PDUs | ||||||
Model | Outlet | Outlet | Model | Outlet | Outlet | Model | Outlet | Outlet | |
Number | Qty. | Type* | Number | Qty. | Type* | Number | Qty. | Type* | |
PDU1215 | 13 | PDUMH15 | 13 | PDUMH15ATNET** | 8 | ||||
PDU1415 | 14 | PDUMV15 | 16 | PDUMV15NET | 16 | ||||
PDUNV | 14 | 2 C19 / 12 C13 | PDUMH15AT** | 8 |
|
|
| ||
PDUV15 | 12 |
|
|
|
|
|
| ||
PDU1220 | 13 | PDUMV20 | 20 | PDUMH20ATNET** | 16 | ||||
PDUNV | 14 | 2 C19 / 12 C13 | PDUMV40 | 32 | PDUMV20NET | 24 | |||
PDU40TDUAL 40 | PDUMH20AT** | 16 |
|
|
| ||||
PDUV20 | 12 | PDUMH20 | 13 |
|
|
| |||
|
|
|
|
|
|
|
|
| |
PDU1220T | 13 | PDUMV20 | 20 | PDUMH20ATNET** | 16 | ||||
PDU1420T | 14 | PDUMV40 | 32 | PDUMV20NET | 24 | ||||
PDU40TDUAL 40 | PDUMH20AT** | 16 |
|
|
| ||||
PDUNV | 14 | 2 C19 / 12 C13 | PDUMH20 | 13 |
|
|
| ||
|
|
|
|
|
|
|
|
| |
PDU2430 | 24 | PDUMV30 | 28 | PDUMV30NET | 24 | ||||
|
|
|
|
|
| PDUMH30NET | 16 | ||
PDUNV | 14 | 2 C19 / 12 C13 | PDUMV20HV | 38 | 6 C19 / 32 C13 | PDUMV20HVNET | 24 | 4 C19 / 20 C13 | |
|
|
|
|
|
|
|
|
| |
PDU1230 | 18 | 2 C19 / 16 C13 | PDUMV30HV | 30 | 6 C19 / 24 C13 | PDUMV30HVNET | 24 | 4 C19 / 20 C13 | |
PDUV30HV | 38 | 6 C19 / 32 C13 |
|
|
| PDUMH30HVNET | 16 | C13 | |
|
|
|
|
|
|
| |||
PDUNV | 14 | 2 C19 / 12 C13 | PDU Part Number Decoder | PDUMH15HVNET | 8 | C13 | |||
|
|
| PDU = Power Distribution Unit |
|
|
| |||
|
|
| M = Metered |
|
|
|
|
| |
|
|
| H = Horizontal |
|
|
|
|
| |
|
|
| V = Vertical |
|
|
|
|
| |
PDUNV | 14 | 2 C19 / 12 C13 |
|
| PDUMH20HVNET | 8 | C13 | ||
AT = ATS with Redundant Input Cords | |||||||||
|
|
| PDUMV20HVNET | 24 | 4 C19 / 20 C13 | ||||
|
|
| NET = Network Card for Remote | ||||||
|
|
|
|
|
| ||||
|
|
| Monitoring and Control |
|
|
| |||
|
|
| HV = High Voltage |
|
|
| |||
|
|
|
|
|
|
|
|
| |
PDU12IEC | 14 | 2 C19 / 12 C13 | PDUMV20HV† | 38 | 6 C19 / 32 C13 | PDUMV20HVNET† | 24 | 4 C19 / 20 C13 | |
|
|
|
|
|
| PDUMH15ATNET**† | 8 | ||
|
|
|
|
|
| PDUMH20ATNET**† | 16 | ||
|
|
|
|
|
|
|
|
|
*
Using a Tripp Lite UPS System
as Power Source Input
The most common application for a PDU is to distribute UPS System power to connected computer equipment. The table below shows common outlet types and a partial list of Tripp Lite UPS Systems that include each outlet type.
| OUTLET | SMARTPRO | SMARTONLINE |
|
| TYPE | UPS SYSTEMS | UPS SYSTEMS |
|
| All | All |
| |
| All | All |
| |
| Select | All 2200VA (120V) |
| |
| All 3000VA (120V) | All 3000VA (120V) |
| |
| Select 5000VA | All 5000VA and Select |
| |
| All 5000VA | All 5000VA and Select |
| |
| C13 | All International Versions | All International Versions |
|
| C19 | All | All |
|
Tripp Lite Power Cords and Adapters
| Model | Description |
|
| C14 to |
| |
| C13 to C14 Power Cable (6 ft.) |
| |
|
| ||
| C13 to |
| |
|
| ||
| C13 to |
| |
|
| ||
| C13 to C20 Power Cable (7 ft.) |
| |
|
| ||
| C19 to |
| |
|
| ||
|
| ||
|
| ||
|
| ||
| UNIPLUGINT | C13 to Wonpro Universal Outlet Adapter (Wonpro outlet is compatible with |
|
|
| more than 20 North American and international plug types.) |
|
2 | Tripp Lite World Headquarters 1111 W. 35th Street, Chicago, IL 60609 USA • (773) |