Tripp Lite Metered PDUs reliably distribute AC power from a UPS system, generator or utility wall outlet to multiple devices. Each model features

a digital load meter that helps you maximize the amount of devices that can be safely added to the PDU (without overloading it) by displaying the

total power consumption of connected equipment. Metered PDUs offer high-quality plug/outlet connections and a switch-free or switch-protected

design to prevent the PDU from being accidentally disconnected or shut down. Versatile all-metal cabinets with detachable mounting hardware

accommodate a variety of mounting options:* wallmount, under-counter and 19-inch rackmount mounting in 1U and/or zero-U formats. Metered

PDUs are available in 15A, 20A, 30Aand 40A capacities. The PDUMV40 model features two separate 20-amp power circuits (with corresponding

color-coded power cord, circuit breaker, load meter and outlets), making it ideal for servers with redundant power supplies and other equipment in

loaded racks. The PDUMV30 model includes high-current 120Vinput with two banks of outlets and dual meters. The PDUMV20HV model

includes 208/230Vinput with C13 and C19 outlets. The PDUMV30HV model includes 208V input with two banks of C13 and C19 outlets and dual

meters. The PDUMV30, PDUMV20HVand PDUMV30HV models also include plug retention brackets that hold connected equipment cables in

place. The PDUMH15ATand PDUMH20ATmodels include redundant inputs with Automatic Transfer Switching (see page 8 for more information)

and are user-upgradeable to switched PDUs (requires SNMPWEBCARD, sold separately).

* See specifications for mounting options supported by each model.
SPECIFICATIONS
Input Input Unit 0U Wallmount/
Input Maximum Plug Outlet Front Rear Cord Dimensions 1U Vertical Under Counter
Model Voltage Input Current Meters Type Qty. & Type(E) Outlets Outlets Length (H x Wx D, in) Rackmount Mount Mount
PDUMH15 120V 15A 1 x 15A 5-15P 13 (5-15R) 1 12 15 ft. 1.75 x 17.5 x 4.5 ✔✔ ✔
PDUMH20 120V 20A 1 x 20A L5-20P / 5-20P(C) 13 (5-15/20R) 1 12 15 ft. 1.75 x 17.5 x 4.5 ✔✔ ✔
PDUMV15 120V 15A 1 x 15A 5-15P 16 (5-15R) 16 n/a 15 ft. 1.5 x 48 x 1.5 n/a ✔✔
PDUMV20 120V 20A 1 x 20A L5-20P / 5-20P(C) 20 (5-15/20R) 20 n/a 15 ft. 1.75 x 60 x 1.25 n/a ✔✔
PDUMV40 120V 2 x 20A 2 x 20A L5-20P / 5-20P(2)(D) 32 (5-15/20R) 32 n/a 2 x 10 ft. 3 x 71.25 x 1.5 n/a ✔✔
PDUMH15AT 120V(A) 15A 1 x 15A 5-15P 8 (5-15R) 8 n/a 2 x 12 ft. 1.75 x 17.5 x 14.5 ✔✔ ✔
PDUMH20AT 120V(A) 20A 1 x 20A L5-20P/ 5-20P(C) 16 (5-15/20R) 8 8 2 x 12 ft. 1.75 x 17.5 x 14.5 ✔✔ ✔
PDUMV30 120V 30A(B) 2 x 20A L5-30P 24 (5-15/20R) 24 n/a 10 ft. 3.75 x 63.75 x 2.25 n/a ✔✔
PDUMV20HV 208/230V 20A(B) 1 x 20A L6-20P(C20 inlet) 38 (32 C13 / 6 C19) 38 n/a 10 ft. 3.75 x 63.75 x 2.25 n/a ✔✔
PDUMV30HV 208V 30A(B) 2 x 15A L6-30P 30 (24 C13 / 6 C19) 30 n/a 10 ft. 3.5 x 63.75 x 2.25 n/a ✔✔
(A)Primary input (fixed cord) tolerances: 99-138V, 45-65Hz. Outside of this range, the PDU switches to the secondary input (detachable cord) if within 99-138Vrange.
Two front panel LEDs marked “primary” and “secondary” indicate the active input source.
(B)Code-derated maximum input current is 80% of value shown.
(C)Includes a twist-lock L5-20P input plug and an adapter to support connection to a straight blade 5-20R outlet. PDUMH20ATincludes (2) cords with twist-lock L5-20Pinput
plugs and (2) adapters to support connection to straight-blade 5-20R outlets.
(D)PDUMV40 is a two-corded, dual-circuit PDU with (2) twist-lock L5-20P plugs and (2) adapters to support connection to straight-blade 5-20R outlets.
(E)5-15/20R outlets accept 5-15P or 5-20Pplugs.
Digital Load Meter Multiple High-Quality Outlets Long Input Cord with High Quality Input Plug AC Circuit Breaker Protection
Secure Mounting Hardware Rugged All-Metal Housing Grounding Lug Twist-Lock L5-20Pto Straight-Blade 5-20P Plug Adapter Dual Circuits
Lighted Power Switch with Safety Cover Cord Retention Bracket
KJ
IHGFE
DCBA
FEATURES
PDUMH15
PDUMH20 has L5-20Pplug, 5-20Pplug adapter and 5-15/20R outlets
PDUMV15
PDUMV20 has L5-20Pplug, 5-20Pplug
adapterand 20 5-15/20R outlets
PDUMV40
Afront panel
rear panel
B
C D
E
F
G
DA
B
C
E(not shown)
JF
F
C
AE(not shown)
BC
IH
FAE(not shown)
D
I
B
Certifications vary by model.
front panel
rear panel
front panel
rear panel
E
C
B
F
A
E
C
B
FA
B
PDUMH15AT PDUMH20AT
H
PDUMV30HV
PDUMV30 has 24 5-15/20R outlets
PDUMV20HVhas C20 inlet, detachable cord with L6-20P, 8 additional C13 outlets and single meter
BA
D
I
K
K