Inverter/Charger DC Volt:12
Wire Gauge
Twin 00 (2/0)
Watts 6 4 2 0 00 (2/0) (RV2012OEM, RV2512OEM & RV3012OEMonly)
500 15 ft 25 ft 39 ft 62 ft 79 ft 158 ft.
700 11 ft 18 ft 28 ft 44 ft 56 ft 112 ft.
1000 N/R 12 ft 20 ft 31 ft 39 ft 78 ft.
2000 N/R N/R N/R 16 ft 20 ft 40 ft.
2400 N/R N/R N/R 13 ft 16 ft 32 ft.
3000 N/R N/R N/R 10 ft 13 ft 26 ft.
N/R = Not Recommended. NOTE: Acceptable power is directly related to cable length (i.e. - the shorter the cable, the better the performance)
2R
SpecificationsLimited Warranty
Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a 30 month period from the date of retail purchase by end user.
Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products.To obtain service under this warrantyyou must obtain a Returned Material Authorization (RMA) number from Tripp Lite or an authorized Tripp Lite service center.Products must be returned to Tripp Liteor an author-
ized Tripp Lite service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered andproof of date and place of purchase.This warranty does not apply to equipment which has been damaged by accident, negligence or misapplication or has been altered or modified
in any way, including opening of the unit’s casing for any reason.This warranty applies only to the original purchaser who must have properly registered the product within 10 days of retail purchase.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.Some states do not permit limitation or exclusion of implied warranties;therefore, the aforesaid limitation(s) or exclusion(s)
may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.Specifically, Tripp Lite is not liable for any
costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise.
Tripp Lite has a policy of continuous improvement.Specifications are subject to change without notice.
Note on Labeling Two symbols are used on the RV labels.
V~:AC Voltage :DC Voltage
Minimum Recommended Cable Sizing Chart
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
MODEL NUMBER: RV612UL RV612ULH RV1012UL RV1012ULH RV1512 RV1512OEM RV2012OEM RV2012UL RV2512OEM RV3012OEM
Series Number: AGAP60012MVJ AGAP60012MVJ AGAP100012MV3 AGAP100012MV3 AGAP200012MV3 AGAP200012MVP3 AGAP200012MVP3 AGAP200012MV3
ACInput Connection: Input Cord Hardwire Input Cord Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire Hardwire
INVERTER
Common Specifications for All Models:•
DC Input Volts (Nominal):12 VDC • · DC Input Voltage Range:10 - 15 VDC • Output Volts (Nominal):120 VAC, ± 5% • Output Frequency (Nominal):60 Hz, ± 0.5% • Efficiency: 88% to 94%, depending on load and temperature
Select Tripp Lite Inverter/Chargers include a Battery Charge Conserver (Load Sense) Control which saves battery power by allowing users to set the minimum load level at which the unit’s
inverter turns on.Users can significantly reduce the No Load DC Input Current (approximately 2.5 to 4 A for all models) to a very low amp level with the use of this control.
Continuous Power (@ 20 C): 600 600 1000 1000 1500 1500 2000 2000 2500 3000
OverPower™ Peak Surge Power:* 900 900 1500 1500 2250 2250 3000 3000 3750 4500
Double Boost™ Peak Surge Power:* 1200 1200 2000 2000 3000 3000 4000 4000 5000 6000
Maximum Output AC Current 5 A 5 A 8.3 A 8.3 A 12.5 A 12.5 A 16.7 A 16.7 A 20 A 25 A
(Continuous):
UL Required DC Fuse TPN-80 (fuse) TPN-80 (fuse) ANL-200 (fuse) ANL-200 (fuse) ANL-275 two ANL-200 (fuses) two ANL-200 (fuses) ANL-325 (fuse) two ANL-200 (fuses) two ANL-275 (fuses)
and Fuse Block: R25100-1CR (fuse block) R25100-1CR (fuse block) 1DK98 (fuse block) 1DK98
(fuse block)
1DK98
(fuse block)
two 1DK98 (fuse blocks) two 1DK98 (fuse blocks) 1DK98
(fuse block) two 1DK98 (fuse blocks) two 1DK98 (fuse blocks)
Bussmann Bussmann Bussmann Busmann Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
(manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer) (manufacturer)
DC Input Current @
Nominal V DC Full Load: 56A 56A 95A 95A 143 A 143 A 192A 190A 240 A 290A
BATTERY CHARGER
Common Specifications for All Models •
Acceptance Volts VDC:Selectable 14.4 V** / 14.2 V Wet** / Gel • Float Volts DC (w/gel):13.3 V (13.6 V) • · Input Volts (Nominal):120 VAC
Charging Capacity DC: 45 A / 11 A** 45 A / 11 A** 55 A / 14 A** 55 A / 14 A** 80 A / 20 A** 80 A / 20 A** 100 A / 25 A** 100 A / 25 A** 120 A / 30 A** 140 A / 35 A**
Input Current AC: 9.5 A 9.5 A 11.5 A 11.5 A 16.7 A 16.7 A 20 A 20 A 24 A 30 A
LINE VAC OPERATION
Common Specifications for All Models •
Input Frequency (Nominal):60 Hz, ±10%
Maximum Input Volts (Transfer to Battery) (Continuous, Charger at Maximum):Selectable 135** or 145 VAC
Minimum Input Volts: Selectable 95** or Selectable 95** or Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85, Selectable 75**, 85,
(Transfer to Battery) 105 VAC 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC 95 or 105 VAC
Maximum Input AC Current 11.3 A 14.5 A 12.1 A 20 A 29 A 29 A 38 A 38 A 44 A 56 A
(Continuous, Charger
at Maximum):
Maximum Bypass ACCurrent: 6 A 6A 12 A 12 A 20 A 15/20 A 15/20 A 20 A 20/20 A 20/20 A
(Load circuit breaker limited)
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting. The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.