10 millisecond automatic transfer between line and battery power supports UPS protection during blackouts and voltage fluctuations for equipment compatible with a one
750 watts continuous AC output in inverter mode
Double Boost inverter output supports momentary startup loads up to 200% of the continuous rating for up to 10 seconds (see specification chart)
OverPower inverter output supports longer duration overloads to 150% for
Protected hardwire
Dual C13 output receptacles pass 120V line power or inverter output through to connected equipment
Reliability enhanced
3 position operating mode switch supports "AUTO" mode to enable automatic transfer between DC and AC modes,
Set of six front panel LEDs display AC/DC operational modes, overload status, DC voltage level, shutdown status and system fault status Set of 4 configuration dip switches support wet/gel battery charging profiles, charger enable/inhibit, and selectable 144/163/182/201V AC low voltage auto transfer during brownouts
Set of 4 additional configuration dip switches support 4 levels of charger limiting relative to output load size, a battery equalization program and battery charger low/high settings
Resettable 3A charger AC input breaker and resettable 4A AC output breaker and automatic
Grounding lug properly connects the inverter/charger system to earth ground or vehicle grounding system
Automatic overload and thermal shutoff safely turns off inverter as excessive loads or overheating conditions develop
Front panel remote control connector enables remote off/on switching (requires APSRM4 switch accessory). Optional APSRM4 accessory also includes
Specifications
OVERVIEW
Intended Application | Emergency Home Power |
|
|
SYSTEM OVERVIEW |
|
Voltage compatibility | 12VDC / 230VAC |
|
|
Frequency | 50 Hz |
compatibility |
|
|
|
OUTPUT |
|
Output watts | INVERTER MODE - 750 watts continuous, Double Boost rated to 1500 watts peak (up to 10 seconds). Overpower |
| rating supports longer term overloads to 1125 watts for up to 15 seconds prior to inverter shutoff. |
|
|
Output nominal | 230V |
voltage |
|
|
|
Output voltage | LINE POWER (AC): Maintains 230V nominal sine wave output from line power source. INVERTER POWER (AC): |
regulation | Maintains PWM sine wave output voltage of 230 VAC |
|
|
Output frequency | 50 Hz (+/- 0.3 Hz) |
regulation |
|
|
|
Outlet quantity / type | 2 AC outlets |
|
|
Overload protection | Includes 3A input breaker dedicated to the charging system and 4A output breaker for AC output loads. |
|
|
Continuous output | 750 |
capacity (watts) |
|
|
|
Peak output capacity | INVERTER MODE - Double Boost rated to 1500 watts peak (up to 10 seconds). Overpower rating supports longer term |
(watts) | overloads to 1125 watts for up to 15 seconds prior to inverter shutoff. |
|
|
INPUT |
|
Input connection | DC INPUT: Set of 2 DC |
type |
|
|
|
Input cord length | DC INPUT: User supplies cabling. 6 gauge or larger (see manual). AC INPUT: |
| IEC |
|
|