900VA/480 watt
Supports
USB port, included USB cable and PowerAlert software offer safe, unattended shutdown without data loss during extended outages
Keyhole mounting flanges enable secure wallmount installation
Specifications
SYSTEM OVERVIEW
Voltage compatibility 120VAC
Frequency60Hz compatibility
OUTPUT
Output VA
Output watts
Output nominal voltage
Output voltage regulation
Output frequency regulation
Outlet quantity / type
INPUT
900
480
120 VAC
Sine wave 120V +14% /
LINE MODE: Passes line frequency of 60Hz
12 NEMA
Maximum input amps
Input connection type
Input cord length
Recommended Electrical Service
BATTERY
12A
NEMA
6 ft / 1.8m
120V 15A
Full load runtime
Half load runtime
DC system voltage
Typical battery lifespan
3 min. (900VA)
10 min. (450VA)
12VDC
3 to 6 years, depending on usage
Battery recharge rate | 2 to 4 hours to reach 90% charge |
|
|
VOLTAGE REGULATION |
|
Voltage regulation | Automatic voltage regulation maintains 120V nominal over an input voltage range of 83V to 147V |
description |
|
|
|
Overvoltage | Output voltage is reduced by 12% as line voltage increases to 128 or higher |
correction |
|
|
|
Brownout correction
Output voltage is boosted by 14% as line voltage decreases to 104V or lower
LEDS ALARMS & SWITCHES
Front panel LEDs
Alarms
2 LEDs indicate line power, battery power/overload status
Audible alarm beeps at regular intervals to indicate battery backup operation. Alarm also sounds during