SPECIFICATIONS
All surge suppressors listed have component response times of less than 1 picosecond.
|
| Nominal | Peak Pulse |
Model: | Description: | Clamping Voltage: | Current: |
DRS232 | RJ45/RJ11 protector for |
|
|
18 volts, protecting |
| ||
| 1340 amps | ||
| (wires | wires | |
|
| ||
| Supplied with a 4” RJ45 patch cable. |
|
|
| RJ45 |
|
|
DNET1 | Token Ring, RS422, AS400/Sys3x | 7.5 volts, protecting |
|
| protector for NICs, hubs, routers, | 750 amps | |
| wires | ||
| etc. Supplied with 4” RJ45 patch |
| |
|
|
| |
| cable. |
|
|
DSUT1CSU | RJ45/RJ11 protector for nonspan |
|
|
powered | 60 volts, protecting |
| |
|
| ||
| service CSUs/DSUs, ISDN “U” | 200 amps | |
| wires | ||
| interfaces or other digital lines. |
| |
|
|
| |
| Supplied with 4” RJ45 patch cable. |
|
|
DTEL2 | RJ45/RJ11 for modems, answering | 260 volts, protecting center |
|
|
| ||
| and fax machines. Supplied with | 250 amps | |
| 4 wires (2 | ||
| 4” RJ11 patch cable. |
| |
|
|
| |
| Serial DB9 RS232 protector for male |
|
|
DB9 | or female ports of data terminal and |
|
|
computing equipment including PCs, |
|
| |
| 18 volts, protecting pins |
| |
| modems, etc. (Any male or female | 340 amps | |
| |||
|
| ||
|
|
| |
| are reversible with reversible |
|
|
| thumbscrews. |
|
|
DB25 | Serial DB25 RS232 protector |
|
|
(wires |
|
| |
| ports of data terminal & computing | 18 volts, protecting pins |
|
| equipment including PCs, printers, |
| |
| 340 amps | ||
| modems, etc. Male/Female genders | ||
|
|
| |
| are reversible with reversible |
|
|
| thumbscrews. |
|
|
|
|
| |
| protector (pins | 18 volts, protecting pins |
|
| male or female DTE/DCE ports. | 340 amps | |
| |||
| Male/Female genders are reversible |
| |
|
|
| |
| with reversible thumbscrews. |
|
|
D10B2 |
|
| |
| 7.5 volts, protecting center, |
| |
| m/f). Also protects IBM 3270 and | 750 amps | |
| shield and chassis | ||
| CCTV lines. |
| |
|
|
| |
DCATV | Coaxial protector for TVs, VCRs, pro | 7.5 volts, protecting center |
|
| 750 amps | ||
| video supplied by CATV (“F” m/f). | and shield conductors | |
|
|
Call Tripp Lite Customer Support at (773)
3