SPECIFICATIONS

All surge suppressors listed have component response times of less than 1 picosecond.

 

 

Nominal

Peak Pulse

Model:

Description:

Clamping Voltage:

Current:

DRS232

RJ45/RJ11 protector for

 

 

100Base-T4, RS232 on twisted Pair

18 volts, protecting

 

 

1340 amps

 

(wires 1-8) or ISDN “S/T” interfaces.

wires 1-8

 

 

 

Supplied with a 4” RJ45 patch cable.

 

 

 

RJ45 100Base-T, 10Base-T,

 

 

DNET1

Token Ring, RS422, AS400/Sys3x

7.5 volts, protecting

 

 

protector for NICs, hubs, routers,

750 amps

 

wires 1-8

 

etc. Supplied with 4” RJ45 patch

 

 

 

 

 

cable.

 

 

DSUT1CSU

RJ45/RJ11 protector for nonspan

 

 

powered T-1 equipment, digital data

60 volts, protecting

 

 

 

 

service CSUs/DSUs, ISDN “U”

200 amps

 

wires 1-8

 

interfaces or other digital lines.

 

 

 

 

 

Supplied with 4” RJ45 patch cable.

 

 

DTEL2

RJ45/RJ11 for modems, answering

260 volts, protecting center

 

 

 

 

and fax machines. Supplied with

250 amps

 

4 wires (2 CO-lines)

 

4” RJ11 patch cable.

 

 

 

 

 

Serial DB9 RS232 protector for male

 

 

DB9

or female ports of data terminal and

 

 

computing equipment including PCs,

 

 

 

18 volts, protecting pins

 

 

modems, etc. (Any male or female

340 amps

 

1-9 and chassis

 

9-pin port). Male/Female genders

 

 

 

 

 

are reversible with reversible

 

 

 

thumbscrews.

 

 

DB25

Serial DB25 RS232 protector

 

 

(wires 1-8, 20) for male or female

 

 

 

ports of data terminal & computing

18 volts, protecting pins

 

 

equipment including PCs, printers,

 

 

1-8, 20 and chassis

340 amps

 

modems, etc. Male/Female genders

 

 

 

 

are reversible with reversible

 

 

 

thumbscrews.

 

 

DB25-ALL

DB25-ALL: Serial DB25 RS232

 

 

 

protector (pins 1-25) for any 25-pin

18 volts, protecting pins

 

 

male or female DTE/DCE ports.

340 amps

 

1-25 and chassis

 

Male/Female genders are reversible

 

 

 

 

 

with reversible thumbscrews.

 

 

D10B2

10Base-2 thin coax protector (BNC

 

 

 

7.5 volts, protecting center,

 

 

m/f). Also protects IBM 3270 and

750 amps

 

shield and chassis

 

CCTV lines.

 

 

 

 

DCATV

Coaxial protector for TVs, VCRs, pro

7.5 volts, protecting center

 

 

750 amps

 

video supplied by CATV (“F” m/f).

and shield conductors

 

 

Call Tripp Lite Customer Support at (773) 869-1234 for additional applications.