Tripp Lite HT1000UPS Manuel du propriétaire, Storage & Service, Basic Operation Rear Panel

Models: HT1000UPS

1 2
Download 2 pages 43.15 Kb
Page 2
Image 2
Basic Operation (Front Panel) (continued)
* Un climatiseur, réfrigérateur, etc.

Basic Operation (Front Panel) (continued)

Storage & Service

Manuel du propriétaire

by the combined equipment load demanding more power than the circuit is designed to sup- ply. If all circuits within a home or office consistently provide low power, the home or office may be served by inadequate utility service or may be in an industrial or commercial area with an overburdened power grid.

3b) “BATTERY CAPACITY” Meter: This meter displays the approximate charge level (in 20% increments) of the UPS's internal battery. During a blackout or severe brownout, the UPS will switch to battery power, the “ON BAT” icon will be illuminated, and the charge level will deplete.

3c) “AVR” (Automatic Voltage Regulation) Icon: This icon will illuminate whenever your UPS is automatically correcting low AC line voltage without depleting battery power. This is a normal, automatic operation of your UPS, and no action is required on your part.

3d) “REPLACE” (Battery Recharge/Replace) Icon: This icon will illuminate and an alarm will sound after a self-test to indicate the UPS battery needs to be recharged or replaced. Allow the UPS to recharge continuously for 24 hours, and repeat the self-test. If the icon continues to illuminate, contact Tripp Lite for service. Battery replacement should only be performed by qualified service personnel. If the UPS requires battery replacement, Tripp Lite offers a complete line of replacement batteries at www.tripplite.com.

3e) “ON BAT” (On Battery) Icon: During a severe brownout or blackout, this icon illu- minates and an alarm sounds (4 short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. Monitor the “Battery Capacity” Meter to determine the approximate battery charge level available to support equipment. During a prolonged brownout or blackout, the alarm will sound continuously (and the “BATTERY CAPACI- TY” Meter will show one 20% capacity segment shaded) to indicate the UPS's batteries are nearly out of power; you should shut down your equipment immediately.

3f) “FAULT” Icon: This icon will illuminate and an alarm will sound after a self-test to indicate the battery-supported outlets are overloaded. To clear the overload, unplug some of your equipment from the battery-supported outlets and run the self-test repeatedly until the icon is no longer illuminated and the alarm is no longer sounding.

CAUTION! Any overload that is not corrected by the user immediately following a self-test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout.

Basic Operation (Rear Panel)

4Surge-Only Protected Outlets: provide surge/line noise protection only, not battery back- up. Plug your components that do not require battery backup (such as receivers, power ampli- fiers, CD players, DVD players, etc.) into these outlets.

5Battery Backup Protected/Surge Protected Outlets: provide both battery backup and surge/line noise protection. Plug your components that require battery backup (such as DLP/LCD bulbs based in rear- and front- projection TVs, personal video recorders PVRs/DVRs such as TiVo®, Media Centers, Media Servers, etc.) into these outlets. DO NOT PLUG LARGE POWER AMPLIFIERS OR OTHER DEVICES WHICH DRAW A HEAVY ELECTRICAL LOAD INTO THESE OUTLETS.

6USB Communication Port: Connects to the USB port on a Media Center PC. Use with PowerAlert Software (available as a FREE website download at www.tripplite.com) to auto- matically and safely shut down a Media Center PC during an extended power failure. Any user-supplied USB cable may be used to connect your UPS to your Media Center PC. Note: This connection is optional. The UPS will work properly without this connection. Also Note: This UPS System automatically provides basic communication compatibility with most inte- grated Windows®, Macintosh® and Linux® power management applications.

7Tel/DSL Protection Jacks: RJ-style jacks protect connected equipment by stopping surges on a single phone, fax or modem line. Connect a phone cord from the wall jack directly to the Tel/DSL jack labeled “IN.” Connect a phone cord from the Tel/DSL jack labeled “OUT” directly to the device to be protected. The UPS system must always be the first item connect- ed in line from the wall jack. The UPS system must be plugged into a 3-wire grounded AC outlet for Tel/DSL line surge protection to work. Connecting your equipment to these jacks is optional. Your UPS will work properly without this connection.

8Coax Protection Jacks: Two sets of gold coaxial “F” connectors protect connected equipment by stopping surges on up to two DSS satellite, cable or antenna lines. Connect a coaxial cable from the wall jack directly to the coaxial jack labeled “IN.” Connect a coaxial cable from the coaxial jack labeled “OUT” directly to the device to be protected. An additional set of coaxial jacks allows for simultaneous connection and protection of an additional device on an additional line (satellite, cable or antenna). Make sure that each device and its corresponding wall jack are connected to corresponding “IN” and “OUT” jacks on the UPS System. The UPS system must always be the first item connected in line from the coaxial wall jacks. The UPS system must be plugged into a 3-wire grounded AC outlet for coaxial line surge protection to work. Make sure coax cables connected to satellite dishes, antennas, etc. are also grounded. Connecting your equipment to these jacks is optional. Your UPS will work properly without these connections.

Battery Replacement (back panel, not shown): Under normal conditions, the original battery in your UPS will last several years. Battery replacement should be performed only by qualified service personnel. During battery replacement, qualified service personnel should refer to “Battery Warnings” in the Safety section and should observe the following procedure: turn the UPS off, unplug the power cord and remove the two screws on the UPS back panel to access the internal battery. Tripp Lite offers a complete line of replacement batteries at www.tripplite.com.

Storage

To avoid battery drain, all connected equipment should be turned off and disconnected from the UPS. Press and hold the ON/OFF button for one second. Your UPS will be completely turned off (deactivated), and will be ready for storage. If you plan on storing your UPS for an extended period, fully recharge the UPS batteries every three months. Plug the UPS into a live AC outlet, turn it on by pressing and holding the ON/OFF button for one second, and allow the batteries to recharge for 24 hours. If you leave your UPS batteries discharged for a long period of time, they will suffer a permanent loss of capacity.

Service

Before returning your UPS for service, follow these steps: 1. Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions. 2. If the problem continues, call Tripp Lite at (773) 869-1233. A service technician will ask for the UPS's model number, serial number and purchase date and will attempt to correct the problem over the phone. 3. If the problem requires service, the technician will issue you a Returned Material Authorization (RMA) number, which is required for service. If you require packaging, the technician can arrange to send you proper packaging. Securely pack the UPS to avoid damage during shipping. Do not use Styrofoam beads for packaging. Any damages (direct, indirect, special, incidental or consequential) to the UPS incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty. UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid. Mark the RMA number on the outside of the package. If the UPS System is within the 2-year warranty period, enclose a copy of your sales receipt. Return the UPS for service using an insured carrier to the address given to you by the Tripp Lite service technician.

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product! *

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

FCC Part 68 Notice (United States Only)

If your Modem/Fax Protection causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance. If advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint with the FCC. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the proper operation of your equipment. If it does, you will be given advance notice to give you an opportunity to maintain uninterrupted service. If you experience trouble with this equipment's Modem/Fax Protection, please call Tripp Lite Technical Support at (773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning. There are no repairs that can be made by the customer to the Modem/Fax Protection. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your state public utility commission or corporation commission for information.)

FCC Radio/TV Interference Notice (U.S. only)

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause undesired operation.

Equipment Attachment Limitations (models with the Industry Canada label in Canada only)

NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets the telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations.

Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.

This product designed and engineered in the USA.

Note on Labeling

Two symbols are used on the label.

V~ : AC Voltage

VStorage & Service : DC Voltage

HT1000UPSSystème d'onduleur UPS

audio-vidéo en attente active

Ne convient pas aux applications mobiles

Importantes consignes de sécurité

CONSERVER CES DIRECTIVES

Ce manuel contient des instructions et des avertissements que vous devez respecter durant l'installation, l'utilisation et l'entreposage des systèmes d'onduleur UPS de Tripp Lite. Ne pas tenir compte de ces mises en garde entraînera l'annulation de la garantie.

Mise en garde concernant l'emplacement de l'onduleur UPS

L'onduleur est conçu pour un usage en environnement contrôlé, à l'abri de l'humidité excessive et de la chaleur ou du froid, des substances corrosives, de la poussière et de la lumière directe du soleil.

Maintenez un dégagement adéquat autour de l'onduleur pour garantir une bonne circulation d'air.

Mises en garde : Connexions de l'onduleur UPS

Connecter votre onduleur directement à une prise de CA correctement mise à la terre. Ne pas brancher l'onduleur sur lui-même, cela l'endommagera.

Ne pas modifier la fiche de l'onduleur et ne pas utiliser d'adaptateur qui éliminerait sa mise à la terre.

Ne pas utiliser d'extensions pour connecter l'onduleur à la prise CA. Votre garantie sera annulée si vous utilisez autre chose que des éliminateurs de surtension de Tripp Lite pour brancher votre onduleur à une prise.

Si une génératrice CA alimente votre onduleur, elle doit fournir une sortie propre, filtrée et classée pour ordinateur.

Mises en garde concernant la connexion de l'équipement

Ne pas utiliser les systèmes d'onduleur UPS Tripp Lite dans les applications médicales de survie où un mauvais fonctionnement ou une panne peuvent entraîner une panne de l'équipement médical de survie ou altérer sa performance de façon importante

Ne pas brancher d'éliminateurs de surtension ou de cordons prolongateurs à la sortie de votre onduleur. Cela pourrait endommager l'onduleur et annuler sa garantie et celle de l'éliminateur de surtensions.

Mises en garde : Batterie

Votre onduleur UPS ne nécessite pas d'entretien de routine. N'ouvrir votre onduleur sous aucun prétexte. Aucune pièce interne ne peut être réparée par l'utilisateur.

Les batteries peuvent présenter un risque de choc électrique et de brûlures dues au courant élevé de court-circuit. Prenez les précautions nécessaires. Ne pas jeter les batteries au feu. Ne pas ouvrir l'onduleur ou les batteries.Ne pas établir de court-circuit ou de pont entre les bornes de la batterie avec un quelconque objet. Débrancher et éteindre l'onduleur avant de remplacer la batterie. Utiliser des outils avec des poignées isolées. Aucune pièce interne de l'onduleur ne peut être réparée par l'utilisateur. Seul le personnel de service autorisé peut remplacer les bat- teries par des batteries du même numéro et du même type (batterie sans entretien). Les batter- ies sont recyclables. Consulter les codes locaux pour les exigences d'élimination des déchets, ou aux E.-U. appeler le 1-800-SAV-LEAD) or le 1-800-8-BATTERY (1-800-822-8837) ou ren- dez visite au pour des renseignements concernant le recyclage : Tripp Lite offre une gamme complète de batteries de remplacement à www.tripplite.com.

Ne pas essayer d'ajouter des batteries externes à votre onduleur.

Installation rapide

ÉTAPE 1 : Placer l'onduleur UPS en position horizontale ou verticale (« tour »). Le boîtier de l'onduleur est conçu avec des côtés qui s'inclinent légèrement de façon à ce que l'afficheur ACL soit orienté vers le haut pour une lecture facile dans les deux positions -horizontale or verticale. Comme autre aide à une lecture facile, on peut faire pivoter l'afficheur ACL. Pour faire pivot- er l'afficheur : Introduire prudemment un petit outil dans les fentes latérales de l'afficheur pour l'extraire du boîtier de l'onduleur; faire pivoter l'afficheur et le remettre en place dans le boîtier.

ATTENTION : Pour que l'onduleur UPS ait un bon équilibre quand il est en position verticale (« tour »), s'assurer que l'afficheur ACL est situé en haut du panneau avant.

ÉTAPE 2 : Brancher l'onduleur UPS dans une prise qui ne partage pas de circuit suppor- tant une lourde charge électrique*.

Après avoir branché l'onduleur UPS dans une prise murale, appuyer sur le bouton ON/OFF pendant une seconde pour le mettre en marche (voir la section Fonctionnement de base). Veuillez prendre note! L'onduleur ne se mettra pas automatiquement en marche en présence de courant de secteur.

ÉTAPE 3 : Connecter votre équipement à l'onduleur UPS. Des prises dédiées (voir schéma) fourniront le secours de batterie et la protection contre les surtensions; brancher vos appareils qui ont besoin d'un secours de batterie (comme les ampoules DLP/LCD des téléviseurs à rétro- projection, les magnétoscopes numériques comme TiVo®, Media Centers, Media Servers, etc.) dans ces prises*. Des prises dédiées (voir schéma) fourniront seulement la protection contre les surtensions; brancher vos appareils qui n'ont pas besoin de secours de batterie (comme les récepteurs, les amplificateurs de puissance, les lecteurs de CD et de DVD, etc.) dans ces prises.

* Votre onduleur est conçu seulement pour protéger les composants de cinéma maison. Vous surchargerez l'onduleur UPS si les

1

2

 

 

Bouton ON/OFF Bouton MUTE/TEST

3a

 

(marche/arrêt)(sourdine/test)

 

 

 

 

 

3b

 

 

 

3c

3f

 

 

3d

3e

6

7

8

3

Port USB

Prises Tél/DSL Prises coaxiales

Afficheur ACL

4 Manuel du propriétaireBasic Operation (Rear Panel)Storage

Prises protégées contre surtension seulement

5

Prises secours de batterie/protégées contre surtension

Fonctionnement de base (panneau avant)

1Bouton « ON/OFF » (marche/arrêt)

Pour mettre l'onduleur UPS en marche : Appuyer sur le bouton ON/OFF pendant une seconde*. S'il n'y a pas de courant de secteur, appuyer sur le bouton fera démarrer l'onduleur « à froid », c.-à-d. le mettra en marche et l'alimentera depuis sa batterie**.

Pour arrêter l'onduleur UPS : Appuyer sur le bouton ON/OFF pendant une seconde*. L'onduleur s'arrêtera complètement (désactivé).

* L'alarme bipera brièvement après une seconde. ** Fournissant du courant au prorata du niveae de charge de la batterie.

2Bouton « MUTE/TEST » (sourdine/test)

Pour éteindre (ou mettre en sourdine) les alarmes de l'onduleur UPS : Appuyer

brièvement et relâcher le bouton MUTE/TEST. Nota : Il est impossible faire taire les alarmes continues (vous avertissant de fermer immédiatement vos appareils connectés).

Pour faire un autotest : Votre onduleur étant branché et mis en marche, appuyer sur le bouton MUTE/TEST pendant deux secondes. Continuer à maintenir le bouton enfoncé jusqu'à ce que l'alarme bipe plusieurs fois et que l'onduleur effectue un autotest. Voir « résultats d'un autotest » ci-dessous. Nota : Vous pouvez laisser votre équipement branché pendant un autotest.

ATTENTION! Ne pas débrancher votre onduleur UPS pour tester ses batteries. Cela supprimera la mise à la terre électrique sécuritaire et peut entraîner une surtension dangereuse pour les connexions de votre réseau.

Résultats d'un autotest : Le test durera environ 10 secondes, le temps que l'onduleur passe sur batteries pour vérifier sa puissance et sa charge. Tous les voyants DEL seront allumés et l'alarme de l'onduleur sonnera.

Si l'icône « FAULT » reste allumée et que l'alarme continue à sonner après le test, les prises de l'onduleur sont surchargées. Pour éliminer la surcharge, débrancher une partie de votre équipement des prises supportées par batterie et exécuter l'autotest à plusieurs repris- es jusqu'à ce que l'icône « FAULT » ne soit plus allumée et que l'alarme ne sonne plus.

ATTENTION!Toute surcharge non corrigée immédiatement par l'utilisateur après l'autotest peut entraîner l'arrêt de l'onduleur UPS et empêcher l'alimentation élec- trique en cas de panne ou de baisse de tension.

Si l'icône « REPLACE » reste allumée et que l'alarme continue de sonner après le test, les batteries de l'onduleur doivent être rechargées ou remplacées. Laisser l'onduleur en charge continue pendant 24 heures et recommencer l'autotest. Si l'icône reste allumée après plusieurs autotests, communiquer avec Tripp Lite pour le service. Le remplacement de batterie doit être effectué seulement par du personnel qualifié. S'il faut remplacer la batterie de l'onduleur, Tripp Lite offre une gamme complète de batteries de remplacement à www.tripplite.com.

3Afficheur ACL

L'afficheur ACL indique les nombreuses conditions de fonctionnement de l'onduleur. Toutes les descriptions s'appliquent lorsque l'onduleur est branché sur une prise CA et mis en marche. L'afficheur ACL peut pivoter pour une lecture facile, que l'onduleur soit en position horizontale ou verticale (« tour »). Pour faire pivoter l'afficheur : Introduire un petit outil dans les fentes latérales de l'afficheur pour l'extraire du boîtier de l'onduleur; faire pivoter l'af- ficheur et le remettre en place dans le boîtier.

1111 W. 35th Street • Chicago, IL 60609 USA

(773) 869-1234 • www.tripplite.com

Copyright © 2005 Tripp Lite. All rights reserved. All copyrights are the property of their respective owners.

charges nominales de tout l'équipement que vous connectez aux prises protégées par batterie de secours/protégées contre des

surtensions transitoires excèdent la puissance de sortie de l'onduleur. Pour trouver la charge nominale en Va de votre équipement,

regarder sur les plaques signalétiques des appareils. Si l'équipement est identifié en ampères, multiplier le nombre d'ampères par

120 pour calculer la puissance. (Exemple : 1 ampère o 120 = 120 VA). Si vous ignorez si les prises, protégées par batterie de sec-

ours/protégées contre des surtensions, sont surchargées, faire un autotest (voir la description du bouton «MUTE/TEST»)

ATTENTION : L'onduleur UPS doit être branché dans une prise de courant active et mis en marche pendant 24 heures après l'installation initiale pour charger complète- ment sa batterie interne. Votre équipement connecté recevra l'alimentation du courant C.A. de secteur (s'il est présent) immédiatement après que l'onduleur a été branché et mis en marche; Il est cependant possible que votre équipement connecté ne reçoive pas de secours de batterie complet en cas de panne ou de baisse de tension avant que la bat- terie interne de l'onduleur ne soit totalement chargée.

3a) Appareil de mesure pour « TENSION D'ENTRÉE » : Cet appareil mesure en temps réel la tension que le système onduleur UPS reçoit de la prise de courant murale.Bien que l'appareil de mesure indique des tensions d'entrée qui dépassent (à cause de la piètre qual- ité du secteur) le registre de la tolérance de l'équipement standard, soyez assuré que l'ond- uleur est conçu (grâce à sa régulation automatique de tension) pour fournir en permanence une tension de sortie stable à l'équipement connecté. Dans le cas d'une panne (panne de courant), d'une sévère baisse de tension (courant trop faible) ou de surtension (courant trop fort) l'onduleur fournira une tension de sortie à l'aide de sa batterie interne. L'appareil de mesure de tension d'entrée peut être utilisé comme outil diagnostique pour identifier la faible qualité du courant de secteur. En branchant l'onduleur dans différentes prises de votre maison ou de votre bureau, vous pouvez identifier les circuits individuels qui fournissent

Page 2
Image 2
Tripp Lite HT1000UPS Manuel du propriétaire, Storage & Service, Basic Operation Rear Panel, Warranty Registration