Alarms
Switches
Audible alarm indicates power failure conditions, silenceable via alarm cancel
2 front panel
SURGE / NOISE SUPPRESSION
AC surge | SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp 100Khz |
suppression | Ringwave and category B BiWave. SURGE VOLTAGE ATTENUATION: |
| INSERTION LOSS: 65 db |
|
|
AC suppression | Instantaneous |
response time |
|
|
|
Dataline | - |
suppression |
|
|
|
EMI / RFI AC noise | Yes |
suppression |
|
|
|
PHYSICAL |
|
Shipping weight | 40 |
(lbs) |
|
|
|
Shipping weight (kg) | 18 |
|
|
Shipping | 18.25 x 12 x 13.75 |
Dimensions |
|
(HWD/in) |
|
|
|
Shipping Dimensions (HWD/cm)
46.4 x 30.5 x 35
Unit weight (lbs) | 36.4 |
|
|
Unit weight (kg) | 16.38 |
|
|
Unit Dimensions | 12.75 x 7.5 x 9.25 |
(HWD/in) |
|
|
|
Unit Dimensions | 32.4 x 19.05 x 23.5 |
(HWD/cm) |
|
|
|
Material of | PVC |
construction |
|
|
|
Form factors | Tower |
supported |
|
|
|
Cooling method | Fan |
|
|
Battery Access | Battery access door |
|
|
ENVIRONMENTAL |
|
Relative Humidity | 0 to 95%, |
|
|
Storage Temperature | +5 to +122 degrees Fahrenheit / |
|
|
Operating | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Temperature |
|
|
|
COMMUNICATIONS |
|
Network monitoring | USB |
port |
|
|
|
Software and | USB cable included; Power Alert software available via free download from www.tripplite.com |
cabling included |
|
|
|
WatchDog | Yes, with optional WATCHDOGSW |
compatibility |
|
|
|
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode