Regulates brownouts as low as 89V back to usable levels without consuming battery power

4 UPS battery-supported/surge-protected outlets plus 4 additional surge suppression-only outlets

USB port and PowerAlert software enables unattended shutdown in case of extended power failure

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.

PowerAlert Software available via free download from www.tripplite.com

650VA/350W power handling ability supports a variety of sensitive computer, home theater and other equipment

3.5 min. full load runtime (650VA/350W), 12 min. half-load runtime (325VA/175W)

Cabinet adapts to tower format or rackmount shelf format. Rackmount (2U) format requires an optional shelf, available separately

2-year product warranty

$200,000 connected equipment insurance (USA & Canada Only).

Specifications

SYSTEM OVERVIEW

Voltage compatibility

120

 

 

Frequency60 compatibility

OUTPUT

Output VA

Output watts

Output nominal voltage

Output voltage regulation

Output frequency regulation

Outlet quantity / type

INPUT

650

350

120VAC

BATTERY MODE: PWM sine wave 115V +/-5%

LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz

8 NEMA 5-15R

Maximum input amps

Input connection type

Input cord length

Recommended Electrical Service

BATTERY

12A

NEMA 5-15P (right-angle plug)

6 ft./1.8 m

120V 15A

Full load runtime

Half load runtime

DC system voltage

Typical battery lifespan

3.5min. (650VA/350W) 12 min. (325VA /175W) 12VDC

4-6 years (depending on usage)

Battery recharge rate

2-8 hours to 90%

 

 

VOLTAGE REGULATION

 

Voltage regulation

Line-interactive voltage regulation corrects brownouts as low as 89V back to usable values

description

 

 

 

Brownout correction

Input voltages between 89V and 104V are boosted by 14%

LEDS ALARMS & SWITCHES

Front panel LEDs

Alarms

Switches

Front panel LCD screen with blue backlight offers continuous input line voltage data, plus UPS status information on line power status, battery power status, battery charge level and voltage regulation operation

Audible alarm with 15-second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain.

Includes 2 front panel switches, one main on/off power switch and one dual-function alarm cancel/self test button

SURGE / NOISE SUPPRESSION

Page 2
Image 2
Tripp Lite OMNI650LCD warranty Specifications