Tripp Lite SMART750XLA warranty Specifications, System Overview, Output, Input, Battery

Models: SMART750XLA

1 4
Download 4 pages 3.04 Kb
Page 2
Image 2
Specifications

SYSTEM OVERVIEW Line-interactive automatic voltage regulation (AVR) maintains selectable 120V, 110V or 100V nominal output during brownouts as low as 83V and overvoltages to 145V

OUTPUT Network interfaces support simultaneous communications via built-in USB port, DB9 serial port and SNMPWEBCARD slot

INPUT HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X BATTERY Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

VOLTAGE REGULATION UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, timed inverter sutoff, activate self-test and output power control

LEDS ALARMS & SWITCHES NEMA 5-15P input plug; 8 battery-supported NEMA 5-15R output receptacles

Manual background Dataline surge suppression protects dialup, DSL or network Ethernet connection

Manual background Front panel LEDs offer current monitoring, voltage regulation and battery charge level information

Manual background UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required Manual background 2-year warranty; $250,000 Ultimate Lifetime Insurance (USA & Canada only)

Specifications

SYSTEM OVERVIEW

Voltage compatibility

120V (110, 100V user selectable)

 

 

Frequency

60 Hz

compatibility

 

 

 

OUTPUT

 

Output VA

750

 

 

Output watts

500

 

 

Output nominal

120, 110, 100V AC

voltage

 

 

 

Output voltage

LINE MODE: Sine wave line voltage 120V (+6%, -10%), 110V (+6%, -10%), 100V (+6%, -10%), BATTERY MODE:

regulation

Sine wave output 120V, 110V, 100V (+/-5%)

 

 

Output frequency

LINE MODE: Passes line frequency of +/-10% BATTERY MODE: Inverter output regulated to 60Hz (+/- 1Hz)

regulation

 

 

 

Outlet quantity / type

8 NEMA 5-15R

 

 

INPUT

 

Maximum input amps

5.4A (120V), 5.8A (110V), 6.4A (100V)

 

 

Input connection type

NEMA 5-15P

 

 

Input cord length

6 ft.

 

 

Recommended

120V 15A

Electrical Service

 

 

 

BATTERY

 

Full load runtime

10 minutes (500w) expandable

 

 

Half load runtime

27 minutes (250w) expandable

 

 

Expandable battery

Runtime is expandable with BP24V28-2U (limit 1) or BP24V70-3U (multi-pack compatible)

runtime

 

 

 

DC system voltage

24VDC

 

 

Battery recharge rate

4.5 hour recharge to 90% (max)

 

 

Replacement Battery

RBC24-SLT

Cartridge

 

 

 

VOLTAGE REGULATION

Voltage regulation description

Overvoltage correction

Brownout correction

Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120, 110, 100V nominal output, without using battery power, during brownouts 95V (120V), 87V (110V), 83V (100V)

Input voltages between 127 and 145V (120V), 116 and 133 (110V), 111 and 121 (100V) are reduced by 12%

Input voltages between 95 and 108 (120V), 87 and 99 (110V), 83 and 93 (100V) are boosted by 14%

LEDS ALARMS & SWITCHES

Page 2
Image 2
Tripp Lite SMART750XLA Specifications, System Overview, Output, Input, Battery, Voltage Regulation, Leds Alarms & Switches