Tripp Lite SMX3000XLRT2U instruction manual Specifications, Output, Input

Models: SMX3000XLRT2U

1 6
Download 6 pages 48.8 Kb
Page 2
Image 2
Specifications

OUTPUT PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands.

Output Volt Amp Capacity (VA) Offers simultaneous monitoring through included USB and DB9 interface ports, or the monitoring by any number of additional servers over IP with included PowerAlert monitoring software.

Output Watt Capacity (watts) Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity

Nominal Output Voltage(s) Supported Emergency Power Off (EPO) interface with cable

Frequency compatibility Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot of connected devices

Built-in UPS output receptacles Supports Tripp Lite's WatchDog software application to restore operation to locked equipment through soft reboot of application, OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications (requires optional WATCHDOGSW)

Output circuit breaker Built-in accessory slot supports SNMP with optional SNMPWEBCARD adapter

INPUT Emergency Power Off (EPO) interface with cable

Manual background Multi-function audible alarms and set of 5 front panel LEDs

Manual background Network-grade AC surge suppression

Manual background Attractive all-black color scheme

Manual background UPS battery set ships fully assembled, no time consuming connection of internal batteries by user is necessary

Specifications

OUTPUT

Output Volt Amp Capacity (VA)

Output kVA capacity (kVA)

Output Watt Capacity (watts)

Output kW capacity

Output power factor

Nominal Output Voltage(s) Supported

Nominal Voltage details

Frequency compatibility

Output voltage regulation (line mode)

Output voltage regulation (Battery mode)

Built-in UPS output receptacles

Included output power cables

Built-in controllable switched load banks

Output circuit breaker

Output AC waveform (AC mode)

Output AC waveform (battery mode)

3000

3

2250

2.2

0.8

230V

230v nominal inverter output voltage

50 / 60 Hz

230V (-15%, +6% )

+/- 5%

8 C13 outlet(s); 1 C19 outlet(s)

Includes 3 C13 to C14 output power cables

Three switchable two-outlet C13 load banks

10A (x2) - each breaker protects 4 C13 outlets, C19 outlet does not include a breaker

Sine wave

Pure Sine wave

INPUT

Page 2
Image 2
Tripp Lite SMX3000XLRT2U instruction manual Specifications, Output Volt Amp Capacity VA Output kVA capacity kVA, Input