Tripp Lite SU20K3/3 warranty Battery, Voltage Regulation, Leds Alarms & Switches, Physical

Models: SU20K3/3

1 5
Download 5 pages 52.36 Kb
Page 3
Image 3
BATTERY

Recommended

120/208V AC (3-Phase, 4 Wire, wye)

Electrical Service

 

 

 

BATTERY

 

Full load runtime

Included internal batteries: 5 min. (16,000 watts). Runtime can be extended with additional internal battery packs (model #

 

SURBC2030).

 

 

Half load runtime

Included internal batteries: 17 min. (8,000 watts). Runtime can be extended with additional internal battery packs (model #

 

SURBC2030).

 

 

Expandable

Supports extended runtime with optional internal battery packs (model # SURBC2030). Accepts 2 additional internal

battery runtime

battery packs. Build to order expandable runtime systems are available. Standalone external battery module (SUBF2030)

 

and built-to-order systems also available.

 

 

DC system voltage

240V DC

 

 

Typical battery

3 - 6 years, depending on usage

lifespan

 

 

 

Battery recharge

2 - 4 hours to 90%

rate

 

 

 

VOLTAGE REGULATION

Voltage regulation description

Overvoltage correction

Brownout correction

On-line, double-conversion process gives this UPS the ability to maintain output voltage within +/-2% of nominal voltage at all times

Maintains continuous operation without using battery power during overvoltages to 144 / 250V AC (3-Phase, 4-Wire, wye), reducing output within 2% of nominal

Maintains continuous operation without using battery power during brownout / undervoltage conditions to 88 / 166V AC (3-Phase, 4-Wire, wye)

LEDS ALARMS & SWITCHES

Front panel LEDs

7 LED DISPLAY: AC input, bypass input, AC-DC charger, DC-AC inverter, AC output, bypass operation and battery

operation. SELECTABLE LCD DISPLAY: indicates a wide range of UPS operational and fault/warning conditions including operational mode, alarm/shutdown conditions, input/output voltage/frequency, battery voltage, load percentage and more.

Alarms

Switches

Alarms warn against a variety of operational conditions: low battery, overload, shutdown, bypass and more

ON button turns UPS's inverter ON. OFF button turns UPS's inverter OFF. Select Button browses through items displayed on LCD screen. Enter button selects items displayed on LCD screen. Select and Enter buttons used simultaneously mute UPS alarms. Battery Start Switch cold starts the inverter. Emergency Power Off button turns UPS output OFF and disables Bypass output. Manual Bypass switch bypasses the UPS's inverter during maintenance.

SURGE / NOISE SUPPRESSION

AC surge

480 joules

suppression

 

 

 

AC suppression

Instantaneous

response time

 

 

 

EMI / RFI AC noise

Yes

suppression

 

 

 

PHYSICAL

 

Shipping weight

609

(lbs)

 

 

 

Shipping weight

276

(kg)

 

 

 

Shipping

43 x 28 x 44.5

Dimensions

 

(HWD/in)

 

 

 

Shipping Dimensions (HWD/cm)

109.2 x 71.1 x 113

Unit weight (lbs)

Unit weight (kg)

Unit Dimensions (HWD/in)

520

236

35.3 x 19.3 x 36

Page 3
Image 3
Tripp Lite SU20K3/3 warranty Battery, Voltage Regulation, Leds Alarms & Switches, Surge / Noise Suppression, Physical