Tripp Lite SU20K3/3 warranty Features, Specifications, System Overview, Output, Input

Models: SU20K3/3

1 5
Download 5 pages 52.36 Kb
Page 2
Image 2
Features

Package Includes

Specifications SU20K3/3 UPS System (power and battery components in one module)

SYSTEM OVERVIEW PowerAlert Software and cabling

OUTPUT Warranty information

INPUT Instruction manual

Features

Manual background Saves valuable space: power and battery components combined into a single small-footprint module

Manual background Simplifies runtime scalability: convenient front-panel battery access for expandable runtime with additional internal battery packs

Manual background True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times

Manual background Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time

Manual background Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems

Manual background 20,000VA / 16,000 watt power capacity with 3-phase, hardwire 120/208V AC input/output connections

Manual background Features a wide input voltage correction range: 88 - 144 / 166 - 250V AC

Manual background Included internal batteries provide 17 minutes runtime at half load (8,000 watts) and 5 minutes runtime at full load (16,000 watts)

Manual background 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands

Manual background Extend runtime by installing optional internal battery packs (model # SURBC2030) through the front panel access door. SU20K3/3 includes 2 internal battery packs and accepts 2 additional internal battery packs. A standalone battery module compartment with a 4 battery pack capacity and daisy-chain capability (model # SUBF2030) is available to further extend runtime.

Manual background 3 communication ports (RS-232, contact closure and AS-400)

Manual background Slot for optional SNMP card (model # SNMPWEBCARD)

Manual background Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing through AC power when the UPS system requires maintenance

Manual background Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval

Manual background Emergency Power Off button turns UPS output OFF and disables Bypass output

Manual background PowerAlert Universal UPS Power Management Software and 6 ft. communication cable included

Manual background 1-year limited repair warranty

Manual background Start-up service program is recommended to enhance the reliability of the installation

Manual background Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities Manual background Combination LED/LCD display

Specifications

SYSTEM OVERVIEW

Voltage

120/208V AC, 3-phase, 4-wire (plus ground), wye

compatibility

 

 

 

Frequency

50/60 Hz (auto-selectable)

compatibility

 

 

 

OUTPUT

 

Output VA

20,000 (20kVA)

 

 

Output watts

16000

 

 

Output nominal

120/208V AC, 3-phase, 4-wire (plus ground), wye

voltage

 

 

 

Output voltage

Maintains pure sine wave output at all times, regulated within 2% of nominal output voltage, less than 3% total harmonic

regulation

distortion (using IGBT Inverter)

 

 

Output frequency

Regulates line frequency at 50 or 60 Hz, +/- 3 Hz

regulation

 

 

 

Outlet quantity /

Hardwire

type

 

 

 

INPUT

 

Maximum input

60A

amps

 

 

 

Input connection

Hardwire

type

 

 

 

Page 2
Image 2
Tripp Lite SU20K3/3 warranty Features, Specifications, System Overview, Output, Input