TriStar SP3010X15AZ Low Flow - Generally, Check For cont’d, Noisy Pump - Check For, Pump Model

Models: SP3010EEAZ SP3210EE SP3215X20 SP3015EEAZ SP3210X15 SP3007X10AZ SP3207EE SP3010X15AZ SP3015X20AZ SP3007EEAZ SP3207X10

1 15
Download 15 pages 18.64 Kb
Page 14
Image 14
____________________________ Page 14 of 15

TriStarPump Series ___________________

____________________________ Page 14 of 15

Low Flow – Generally, Check For: (cont’d.)

2.Undersized pool piping. Solution: Correct piping size.

3.Plugged or restricted discharge line of filter, valve partially closed (high gauge reading).

Solution: Sand filters – backwash as per manufacturer’s instructions; D.E. filters – backwash as per manufacturer’s instructions; Cartridge filters – clean or replace cartridge.

4.Air leak in suction (bubbles issuing from return fittings).

Solution: Re-tighten suction and discharge connections using Teflon tape. Inspect other plumbing connections and tighten as required.

5.Plugged, restricted, or damaged impeller. Solution: Replace including new seal assembly.

Noisy Pump – Check For:

1.Air leak in suction piping, cavitations caused by restricted or undersized suction line or leak at any joint, low water level in pool, and unrestricted discharge return lines.

Solution: Correct suction condition or throttle return lines, if practical. Holding hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting.

2.Vibration due to improper mounting, etc.

Solution: Mount the pump on a level surface and secure the pump to the equipment pad.

3.Foreign matter in pump housing. Loose stones/debris hitting impeller could be cause. Solution: Clean the pump housing.

4.Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine.

Solution: All seal leaks should be replaced at once.

© Hayward Pool Products, Inc. 2005 All rights reserved.

PRODUCT REGISTRATION

(Retain For Your Records)

DATE OF INSTALLATION ____________________

 

INITIAL PRESSURE GAUGE READING (CLEAN FILTER)

_______________________

PUMP MODEL ________________

HORSEPOWER

_______________________

FILTER MODEL ________________

SERIAL NUMBER

_______________________

 

 

 

WWW.HAYWARDPOOL.COM

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS