TriStarPump Series __________

_____

________________________________Page 3 of 15

WARNING It is required that licensed electricians do all electrical wiring. Risk of

Electric Shock. Hazardous voltage can shock, burn, and cause death or serious property damage. To reduce the risk of electric shock, do NOT use an extension cord to connect unit to electric supply. Provide a properly located electrical receptacle. All electrical wiring MUST be in conformance with applicable local and national codes and regulations. Before working on pump or motor, turn off power supply to the pump.

WARNING To reduce the risk of electric shock replace damaged wiring immediately. Locate conduit to prevent abuse from lawn mowers, hedge trimmers and other equipment.

WARNING Install a Ground Fault Circuit Interrupter (GFCI) in the circuit. For size of GFCI required and test procedures for GFCI, see manufacturer’s instructions. Pump MUST be permanently connected to GFCI.

WARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death. To reduce the risk of electric shock, see installation instructions and consult a professional electrician on how to bond pump. Also, contact a licensed electrician for information on local electrical codes for bonding requirements.

Notes to the electrician:

Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm2) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5

m)of inside walls of swimming pool, spa, or hot tub. IMPORTANT - Reference NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures.

WARNING Suction Entrapment Hazard.

Suction in suction outlets and/or suction outlet covers which are damaged, broken, cracked, missing, or

unsecured cause severe injury and/or death due to the following entrapment hazards:

Hair Entrapment- Hair can become entangled in suction outlet cover.

Limb Entrapment- A limb inserted into an opening of a suction outlet sump or suction outlet cover that

is damaged, broken, cracked, missing, or not securely attached can result in a mechanical bind or swelling of the limb.

Body Suction Entrapment- A differential pressure applied to a large portion of the body or limbs can result in an entrapment.

Evisceration/ Disembowelment- A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration/disembowelment.

Mechanical Entrapment- There is potential for jewelry, swimsuits, hair decorations, fingers, toes, or knuckles to be caught in an opening of a suction outlet cover resulting in mechanical entrapment.

WARNING - To Reduce the risk of Entrapment Hazards:

- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3’) [0.91 meter] apart, as measured from near point to near point.

- Dual suction fittings shall be placed in such locations and distances to avoid “dual blockage” by

auser.

-Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas.

-The maximum system flow rate shall not exceed the values shown in the “Pipe Sizing Chart” found at the bottom of page 5 of this manual.

-Never use pool or spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.

-Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.

-In addition to two or more suction outlets per pump installed in accordance with latest IAF (formerly NSPI) standards and CPSC guidelines, follow all national, state, and local codes applicable.

-Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.

WWW.HAYWARDPOOL.COM

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Page 3
Image 3
TriStar SP3010X15AZ, SP3207X10, SP3007EEAZ, SP3015X20AZ, SP3207EE, SP3007X10AZ USE only Hayward Genuine Replacement Parts

SP3010EEAZ, SP3210EE, SP3215X20, SP3015EEAZ, SP3210X15 specifications

The TriStar range of pressure and temperature transmitters, specifically the models SP3010EEAZ, SP3010X15AZ, SP3215X20, SP3207X10, and SP3210X15, showcases advanced technologies tailored for precision in industrial applications. These transmitters are engineered to provide accurate readings under a variety of conditions, enhancing the efficiency and reliability of processes.

The SP3010EEAZ is designed for temperature measurement, utilizing a highly sensitive sensor that offers a wide temperature range. Its robust construction makes it ideal for harsh environments, ensuring durability and longevity. This model features advanced signal processing algorithms that minimize noise and improve measurement accuracy. Additionally, it supports multiple output options, allowing for versatile integration into existing systems.

Similarly, the SP3010X15AZ is a versatile pressure transmitter known for its compact design and high-performance characteristics. It employs piezoresistive sensing technology, which ensures quick response times and exceptional stability over time. The SP3010X15AZ is capable of measuring both gauge and absolute pressures, making it suitable for various applications across different industries. Its digital display provides real-time readings, enhancing operational oversight.

The SP3215X20 extends the range of capabilities with its dual functionality, measuring both pressure and temperature. Featuring an intuitive user interface, it allows for straightforward calibration and adjustment. This model incorporates advanced diagnostics, which can alert users to potential issues, ensuring that system integrity is maintained.

On the other hand, the SP3207X10 is a specialized transmitter with a focus on high-pressure applications. Equipped with reinforced housing and advanced sealing technologies, it offers unparalleled resistance to extreme conditions. Its design prioritizes safety, making it a reliable choice for critical processes.

Lastly, the SP3210X15 combines cutting-edge technology with user-friendly features. Its modular design allows for easy maintenance and upgrades, making it adaptable for evolving industrial needs. With high accuracy and a broad operational range, this model is perfect for applications requiring precise pressure and temperature monitoring.

In summary, the TriStar SP series transmitters exemplify innovation in pressure and temperature measurement. Their combination of advanced sensor technologies, user-centric designs, and robust construction positions them as ideal solutions for industrial applications, ensuring enhanced performance and reliability across various operational settings.