Section 7: Wall Mounted Thermostat Wiring For 120/240 Volt
ATTENTION
•Install main power connection with appropriate voltage as per Section C or Section D.
•Install a 2 conductor wire with ground
(3 wires total) from the thermostat wall box to the junction box on the unit.
•Wiring of the thermostat must be completed prior to the mounting of the unit.
•The following installation instructions are for a single pole thermostat.
1.Loosen the screw securing the junction box and remove the cover.
2.Remove the knockouts (if necessary) or use the provided cable clamp.
3.Pull out the three wires marked T1, T2, and TG. (red, red, and green)
4.Remove the wire connector and separate the wires marked T1 & T2.
5.Connect the (red) T1 wire from the unit to the white (neutral) wire from the wall thermostat box by using a wire connector.
(not supplied)
6.Connect the other end of the white
(neutral) wire from the thermostat wall box to the red wire from the wall thermostat.
7.Connect the (red) T2 wire from the unit to the black wire from the thermostat wall box by using a wire connector.
(not supplied)
8.Connect the other end of the black wire from the thermostat wall box to the black wire from the wall thermostat.
9.Connect the green (ground) TG wire from the unit to the green (ground) wire from the thermostat wall box by using a wire connector. (not supplied)
10.Connect the other end of the green
(ground) wire from the thermostat wall box to the back plate of the wall mounted thermostat with a ground screw.
11.Ensure that all connections are tight.
12.Insert all the wiring of the wall mounted thermostat into the wall box.
13.Insert all the wiring back into the unit and secure with a cable clamp.
JUNCTION BOX
Junction Box Locator: Figure 10